MRI has a high false positive rate for women with a hereditary risk of breast cancer, but ...

26.03.2008
... new research shows this has little impact on their choice for preventive mastectomy

Magnetic resonance imaging (MRI) falsely detects breast cancer in five out of every six positive scans according to new research into the use of MRI for women with a high, inherited risk of developing the disease. However, this high rate of false positives does not have a major impact on a woman’s decision whether or not to have a prophylactic mastectomy.

The study, published today (Wednesday 26 March) in the April issue of the cancer journal, Annals of Oncology [1], also showed that MRI was very good at detecting genuine cases of invasive cancers and ductal carcinoma in situ (DCIS), a localised pre-cancer that can develop into invasive breast cancer, although the authors said that improvements in detection were still necessary.

The researchers from the Hereditary Cancer Clinic at Radboud University Nijmegen Medical Centre, Nijmegen, The Netherlands, followed 196 women with a BRCA1 or BRCA2 mutation, aged between 21 and 68 for an average of two years (a range of between one and nine years). Once the women had discovered that they carried a BRCA mutation (which gives a lifetime risk of breast cancer of up to 85 per cent and for ovarian cancer of up to 60 per cent) they made six-monthly visits to hospital to be examined by an experienced medical specialist and to have a mammography and, whenever possible, MRI. During their first surveillance visit, the researchers recorded whether the women had a preference for ongoing surveillance, or prophylactic mastectomy and/or a prophylactic salpingo-oophorectomy (removal of fallopian tubes and ovaries).

During the period of the study, which ran from 1999 to 2005, 41 per cent (81 of 196) of the women had at least one positive MRI or mammogram; breast cancer was detected in 17 women (11 from scanning, four during prophylactic mastectomy and two during the interval between surveillance visits). The researchers found that the sensitivity of mammography (the proportion of true positives) was 41 per cent, for MRI it was 60 per cent and for the two combined it was 71 per cent. The specificity of the techniques (proportion of true negatives) was 93 per cent for mammography and 90 per cent for MRI or a combination of the two.

The lead author of the study, Dr Nicoline Hoogerbrugge, associate professor and head of the Hereditary Cancer Clinic, said: “When we looked at the positive MRI results, we found that 83 per cent of them could not be confirmed histologically and were, therefore, false positives: five out of every six positive MRI scans.”

The researchers also found that approximately six per cent of the BRCA mutation carriers who had normal findings from their clinical surveillance, mammograms and MRIs, and who underwent an intended prophylactic mastectomy, had an unsuspected malignancy. One was only four millimetres in size and it is known that MRI and mammograms have difficulty detecting lesions this small, but three were DCIS between six and 15mm. “This indicates that further improvement of early breast cancer detection is still necessary,” said Dr Hoogerbrugge.

When interviewed during their first surveillance visit, 58 women (30 per cent) expressed a preference for a prophylactic mastectomy. Three had no preference, and the rest preferred to have ongoing surveillance. After some of these women had a positive scan, mastectomy was carried out in 90 per cent of those women who had expressed a preference for it, and in only 31 per cent of those who had preferred surveillance.

Dr Hoogerbrugge said: “During the first two years after the establishment of a BRCA mutation, four out of every ten female carriers were confronted with an abnormal MRI or mammography result, but this had a limited impact on their choice for prophylactic mastectomy. The final decision to actually undergo prophylactic mastectomy appeared to be determined more frequently by a woman’s prior preference than by a positive scan. Significantly more women with a prior preference for prophylactic mastectomy opted for it after a positive scan than did women without such prior intention. We found that women with a mother with breast cancer were more likely to have a preference for mastectomy.”

She said personal beliefs and the psychological impact of women’s family medical histories seemed to be of major importance in women’s decision-making process. “There are very few data available about how women decide upon prophylactic mastectomy. Both genetic counselling and breast cancer surveillance are events in the entire process of decision-making, but appear to have a limited impact.

“However, the fact that a false positive MRI result has little impact on a woman’s choice of prophylactic mastectomy may indicate that she has made a well-balanced decision on this subject.”

The researchers say that while the pros and cons of prophylactic mastectomy for BRCA mutation carriers remain controversial, with the effects on length and quality of life largely unknown, physicians should give detailed and unbiased information on the different treatments available and the breast cancer risk, including the number of malignancies that are not identified during breast cancer surveillance.

Dr Hoogerbrugge said: “It is important to give BRCA mutation carriers correct risk information for the decision process, because preventive surgery is irreversible.”

She concluded: “This study has made me realise that for women at high hereditary risk of breast cancer, accurate detection techniques are of the utmost importance, even at the cost of a high false positive rate because most women can cope with a false positive MRI result.”

Notes:
[1] The impact of a false-positive MRI on the choice for mastectomy in BRCA mutation carriers is limited. Annals of Oncology. doi:10.1093/annonc/mdm537. Ann Oncol 2008; 19: 655-659.

Emma Mason | alfa
Further information:
http://www.oxfordjournals.org/our_journals/annonc/press_releases/freepdf/mdm537.pdf

More articles from Medical Engineering:

nachricht Novel PET tracer identifies most bacterial infections
06.10.2017 | Society of Nuclear Medicine and Molecular Imaging

nachricht Teleoperating robots with virtual reality
05.10.2017 | Massachusetts Institute of Technology, CSAIL

All articles from Medical Engineering >>>

The most recent press releases about innovation >>>

Die letzten 5 Focus-News des innovations-reports im Überblick:

Im Focus: Neutron star merger directly observed for the first time

University of Maryland researchers contribute to historic detection of gravitational waves and light created by event

On August 17, 2017, at 12:41:04 UTC, scientists made the first direct observation of a merger between two neutron stars--the dense, collapsed cores that remain...

Im Focus: Breaking: the first light from two neutron stars merging

Seven new papers describe the first-ever detection of light from a gravitational wave source. The event, caused by two neutron stars colliding and merging together, was dubbed GW170817 because it sent ripples through space-time that reached Earth on 2017 August 17. Around the world, hundreds of excited astronomers mobilized quickly and were able to observe the event using numerous telescopes, providing a wealth of new data.

Previous detections of gravitational waves have all involved the merger of two black holes, a feat that won the 2017 Nobel Prize in Physics earlier this month....

Im Focus: Smart sensors for efficient processes

Material defects in end products can quickly result in failures in many areas of industry, and have a massive impact on the safe use of their products. This is why, in the field of quality assurance, intelligent, nondestructive sensor systems play a key role. They allow testing components and parts in a rapid and cost-efficient manner without destroying the actual product or changing its surface. Experts from the Fraunhofer IZFP in Saarbrücken will be presenting two exhibits at the Blechexpo in Stuttgart from 7–10 November 2017 that allow fast, reliable, and automated characterization of materials and detection of defects (Hall 5, Booth 5306).

When quality testing uses time-consuming destructive test methods, it can result in enormous costs due to damaging or destroying the products. And given that...

Im Focus: Cold molecules on collision course

Using a new cooling technique MPQ scientists succeed at observing collisions in a dense beam of cold and slow dipolar molecules.

How do chemical reactions proceed at extremely low temperatures? The answer requires the investigation of molecular samples that are cold, dense, and slow at...

Im Focus: Shrinking the proton again!

Scientists from the Max Planck Institute of Quantum Optics, using high precision laser spectroscopy of atomic hydrogen, confirm the surprisingly small value of the proton radius determined from muonic hydrogen.

It was one of the breakthroughs of the year 2010: Laser spectroscopy of muonic hydrogen resulted in a value for the proton charge radius that was significantly...

All Focus news of the innovation-report >>>

Anzeige

Anzeige

Event News

ASEAN Member States discuss the future role of renewable energy

17.10.2017 | Event News

World Health Summit 2017: International experts set the course for the future of Global Health

10.10.2017 | Event News

Climate Engineering Conference 2017 Opens in Berlin

10.10.2017 | Event News

 
Latest News

Electrode materials from the microwave oven

19.10.2017 | Materials Sciences

New material for digital memories of the future

19.10.2017 | Materials Sciences

Physics boosts artificial intelligence methods

19.10.2017 | Physics and Astronomy

VideoLinks
B2B-VideoLinks
More VideoLinks >>>