Newest screen for newborns will indicate heart problems

Now a group of physicians and scientists has published an important paper that recommends strategies for national screening for critical CHD, using a simple, noninvasive test called pulse oximetry that measures oxygen in blood. Low oxygen levels would trigger further investigation.

The screening strategy report was published in the journal Pediatrics on Aug. 22.

“Screening for low-blood oxygen saturation can be an effective way to identify otherwise well-appearing babies who have undetected critical CHD,” said one of the report's authors, Alex Kemper, M.D., Associate Professor of Pediatrics at Duke University Medical Center. “One of the biggest challenges in implementing screening will be the follow-up after a positive screen.”

Many of the identified babies will require an evaluation by a pediatric cardiologist or an echocardiogram, or ultrasound of the heart, before they can go home. Because not all hospitals have these services, some babies may need to be transferred to other hospitals.

“Therefore, it is very important to avoid false positive screening results,” Kemper said. “We believe that the strategy we have developed will identify most cases but also have a false positive rate of less than 1 percent.”

The group's recommendations are based on large studies conducted in the United States and Europe. However, there are still many unanswered questions about how to best screen, including timing and the standards for a positive screen.

For example, the algorithm's usual cutoff point for oxygen saturation may need to be adjusted for babies in high-altitude nurseries, where blood oxygen levels may be normally slightly lower.

“We expect that as screening is adopted, these recommendations will be improved, but there is good evidence that this screening can save lives,” Kemper said.

The report was endorsed by the American Academy of Pediatrics, the American College of Cardiology Foundation, and the American Heart Association.

Based on evidence that has already been gathered, the state of New Jersey will initiate CCHD screening on Aug. 31 for all babies before discharge.

“This will be a great opportunity for other states to learn how to begin screening on a wide scale,” Kemper said.

As more information is learned about how to safely and effectively screen newborns, other states are likely to adopt similar rules. In addition, the Secretary of Health and Human Services is now developing a plan to assist states in the identification and treatment of newborns with congenital heart disease.

Pulse oximetry is a noninvasive test that under the new recommendations would be applied to the right hand and a foot of a newborn, to get two different readings of oxygen levels in blood. Pulse oximetry uses light at different wavelengths that passes painlessly through the patient's skin and then measured by a detector to determine the percentage of oxygen-bound blood. A low level can result from CHD, certain infections, or other serious health problems. For screening, testing should ideally occur after the baby is 24 hours old, because there are many changes in the circulatory system very early in life that can cause a false positive screen.

For further information, please find the article in the latest issue of Pediatrics, at http://pediatrics.aappublications.org/

Media Contact

Mary Jane Gore EurekAlert!

More Information:

http://www.duke.edu

All latest news from the category: Health and Medicine

This subject area encompasses research and studies in the field of human medicine.

Among the wide-ranging list of topics covered here are anesthesiology, anatomy, surgery, human genetics, hygiene and environmental medicine, internal medicine, neurology, pharmacology, physiology, urology and dental medicine.

Back to home

Comments (0)

Write a comment

Newest articles

Sea slugs inspire highly stretchable biomedical sensor

USC Viterbi School of Engineering researcher Hangbo Zhao presents findings on highly stretchable and customizable microneedles for application in fields including neuroscience, tissue engineering, and wearable bioelectronics. The revolution in…

Twisting and binding matter waves with photons in a cavity

Precisely measuring the energy states of individual atoms has been a historical challenge for physicists due to atomic recoil. When an atom interacts with a photon, the atom “recoils” in…

Nanotubes, nanoparticles, and antibodies detect tiny amounts of fentanyl

New sensor is six orders of magnitude more sensitive than the next best thing. A research team at Pitt led by Alexander Star, a chemistry professor in the Kenneth P. Dietrich…

Partners & Sponsors