Forum for Science, Industry and Business

Sponsored by:     3M 
Search our Site:

 

Non-invasive MRI technique distinguishes between Alzheimer’s and frontotemporal dementia

20.06.2005


Arterial spin labeling distinguishes between Alzheimer’s disease and frontotemporal dementia



A non-invasive magnetic resonance imaging (MRI) technique called arterial spin labeling is just as accurate as invasive scanning techniques in distinguishing Alzheimer’s disease from frontotemporal dementia (FTD) in the brains of elderly people, according to a new study at the San Francisco VA Medical Center (SFVAMC).

The study, led by Norbert Schuff, PhD, a Principle Investigator at SFVAMC, used arterial spin labeling to measure perfusion, or blood flow, in the areas of the brain affected by the two diseases. "Blood flow indicates brain activation," said Dr. Schuff. "So the area with less blood flow is the area affected by disease." In the study, arterial spin labeling successfully distinguished between Alzheimer’s patients, FTD patients, and people without dementia.


Antao Du, PhD, SFVAMC Research Scientist and study co-author, is presenting the results at the first International Conference on Prevention of Dementia, which is being held June 18-21 in Washington, D.C. The conference is sponsored by the Alzheimer’s Association.

Frontotemporal dementia is a degenerative condition involving the front part of the brain. It is the second-most common dementia after Alzheimer’s disease, which mainly affects other brain areas such as the hippocampus and the temporal lobe. In their early stages, the two diseases present similar symptoms, making accurate diagnosis difficult, said Schuff, who is also an associate professor of radiology at the University of California, San Francisco (UCSF). In its later stages, FTD affects social conduct, social inhibitions, and personality, while Alzheimer’s is a progressive impairment of multiple cognitive functions, often involving memory decline. "Progression of frontotemporal dementia is usually faster than Alzheimer’s, and the underlying pathology is different, so it is important to know the difference," Schuff observed.

Currently, brain blood flow can be measured using positron emission tomography (PET) and single proton emission computerized tomography (SPECT). However, these techniques involve injecting patients with radioactive tracers. In addition, Schuff noted, they can be expensive -- about $2,000 for a PET scan -- can take up to half a day to perform, and are not widely available. "So if you can acquire blood flow information with MRI, that would be very beneficial. MRI is totally non-invasive, making it much safer for patients. It’s more widely available, it’s cheaper, and arterial spin labeling can be done in ten minutes together with a conventional MRI scan."

In simple terms, MRI is a non-radioactive imaging technique that measures the magnetic alignment of protons in the body. In arterial spin labeling, a technique invented by researchers at the University of Pennsylvania, protons in arterial blood are magnetically aligned in the opposite direction from the rest of the protons in blood and brain tissue. By measuring the intensity of the magnetic signal from these so-called inversely polarized protons when they reach the brain, researchers can calculate the amount of blood flow, and thus neuron activity, in a particular section of the brain.

In the study, Schuff and his fellow researchers measured brain perfusion in 24 Alzheimer’s patients, 21 FTD patients, and 25 control subjects without dementia. The subjects were 62 to 90 years old, with an average age of just under 63. They were studied using an MRI system with a magnetic field strength of 1.5 Tesla, a common system in clinics and hospitals in the United States. The researchers successfully used arterial spin labeling to replicate PET and SPECT data on brain perfusion in all subjects. They also found that the perfusion data, added to structural information about the brain obtained with conventional MRI, significantly improved the classification of FTD from normal aging. Thus, "we gained specificity and sensitivity," said Schuff.

Schuff emphasized that because this was a research study, the aim of which was to accurately replicate PET and SPECT perfusion data, it did not prove that arterial spin labeling can be used to diagnose an individual patient. The next step for future research, he said, is to demonstrate that the perfusion abnormalities correlate with specific clinical symptoms. "At the moment, we have just dichotomized [patients] into Alzheimer’s and FTD," he said. "But of course cognitive impairment is usually more complex -- you have a range of impairments."

The technique has the potential to distinguish other types of dementia as well. Schuff plans to study a larger sample in a clinical setting, with the goal of determining whether this is possible. "Once we have a large database of images," he predicted, "we can better determine what is normal, and then compare an individual subject with this normal range."

Schuff intends to continue his studies using a more powerful MRI system that operates at a magnetic field strength of 4 Tesla. This state-of-the art system was recently installed at SFVAMC with support funds from the National Institutes of Health (NIH) and the Department of Defense. "At 4 Tesla, measurements of brain blood flow will be more accurate than at 1.5 Tesla due to a higher signal intensity and prolonged lifetime of the polarized protons," Schuff said.

Steve Tokar | EurekAlert!
Further information:
http://www.ucsf.edu
http://www.ncire.org

More articles from Health and Medicine:

nachricht Foods of the future
15.08.2018 | Georg-August-Universität Göttingen

nachricht New antibody analysis accelerates rational vaccine design
09.08.2018 | Scripps Research Institute

All articles from Health and Medicine >>>

The most recent press releases about innovation >>>

Die letzten 5 Focus-News des innovations-reports im Überblick:

Im Focus: Unraveling the nature of 'whistlers' from space in the lab

A new study sheds light on how ultralow frequency radio waves and plasmas interact

Scientists at the University of California, Los Angeles present new research on a curious cosmic phenomenon known as "whistlers" -- very low frequency packets...

Im Focus: New interactive machine learning tool makes car designs more aerodynamic

Scientists develop first tool to use machine learning methods to compute flow around interactively designable 3D objects. Tool will be presented at this year’s prestigious SIGGRAPH conference.

When engineers or designers want to test the aerodynamic properties of the newly designed shape of a car, airplane, or other object, they would normally model...

Im Focus: Robots as 'pump attendants': TU Graz develops robot-controlled rapid charging system for e-vehicles

Researchers from TU Graz and their industry partners have unveiled a world first: the prototype of a robot-controlled, high-speed combined charging system (CCS) for electric vehicles that enables series charging of cars in various parking positions.

Global demand for electric vehicles is forecast to rise sharply: by 2025, the number of new vehicle registrations is expected to reach 25 million per year....

Im Focus: The “TRiC” to folding actin

Proteins must be folded correctly to fulfill their molecular functions in cells. Molecular assistants called chaperones help proteins exploit their inbuilt folding potential and reach the correct three-dimensional structure. Researchers at the Max Planck Institute of Biochemistry (MPIB) have demonstrated that actin, the most abundant protein in higher developed cells, does not have the inbuilt potential to fold and instead requires special assistance to fold into its active state. The chaperone TRiC uses a previously undescribed mechanism to perform actin folding. The study was recently published in the journal Cell.

Actin is the most abundant protein in highly developed cells and has diverse functions in processes like cell stabilization, cell division and muscle...

Im Focus: Lining up surprising behaviors of superconductor with one of the world's strongest magnets

Scientists have discovered that the electrical resistance of a copper-oxide compound depends on the magnetic field in a very unusual way -- a finding that could help direct the search for materials that can perfectly conduct electricity at room temperatur

What happens when really powerful magnets--capable of producing magnetic fields nearly two million times stronger than Earth's--are applied to materials that...

All Focus news of the innovation-report >>>

Anzeige

Anzeige

VideoLinks
Industry & Economy
Event News

Within reach of the Universe

08.08.2018 | Event News

A journey through the history of microscopy – new exhibition opens at the MDC

27.07.2018 | Event News

2018 Work Research Conference

25.07.2018 | Event News

 
Latest News

Unraveling the nature of 'whistlers' from space in the lab

15.08.2018 | Physics and Astronomy

Diving robots find Antarctic winter seas exhale surprising amounts of carbon dioxide

15.08.2018 | Earth Sciences

Early opaque universe linked to galaxy scarcity

15.08.2018 | Physics and Astronomy

VideoLinks
Science & Research
Overview of more VideoLinks >>>