Infrared imaging to measure glymphatic function

Infrared cerebrospinal fluid tracer dynamically imaged with the LICOR Pearl IR imaging system allows assessment of tracer movement over the surface of the cerebral convexity as a surrogate measure of glymphatic exchange.
Credit: S.A. Keil et al., doi 10.1117/1.NPh.9.2.021915

Dynamic infrared tracer imaging uses affordable and widely available equipment to obtain the temporal resolution necessary to evaluate glymphatic flux within the brain.

The glymphatic system facilitates fluid exchange in the central nervous system and clears dissolved wastes. This anatomically organized movement occurs primarily during sleep and is supported by astroglial neural cells via water channels called aquaporins. These channels line the perivascular pathways and facilitate cerebrospinal fluid and interstitial fluid exchange throughout the brain.

Glymphatic dysfunction has been implicated in numerous pathological conditions, including Alzheimer’s disease, traumatic brain injury, and stroke. Existing methods for assessing glymphatic function have been challenging. Dynamic methods such as 2-photon microscopy and contrast-enhanced magnetic resonance imaging (MRI) require expensive instrumentation and specific technical skills, yet they have other limitations. For instance, 2-photon microscopy cannot reliably access deeper brain regions. The more readily implemented and widely used method of slice-based fluorescent imaging permits assessment at only a snapshot of a single time point, so obtaining a view across time requires many animals and much effort.

To address the need for combined dynamic imaging and histologic assessment in glymphatic research, a team of researchers at the US Department of Veterans Affairs (VA) Puget Sound Health Care System and the University of Washington (UW) in Seattle recently developed a straightforward and novel dynamic imaging paradigm as a surrogate measure of glymphatic flux within the brain. As reported in Neurophotonicsthe technique uses a widely available small animal infrared (IR) imaging system (LICOR Pearl) to obtain a sensitive dynamic surrogate measure of glymphatic exchange. It does so by tracking the distribution of an IR tracer in cerebrospinal fluid in real time over the cortical surface of a living mouse brain.

The technique enables measurement of the temporal dynamics of glymphatic functions, as well as the ability to follow up with the gold standard slice-based fluorescence analysis and histological evaluation for concurrent visualization of resolution of deeper structures. This approach allows both dynamic and structural insights to be assessed in parallel. The technique works great for research involving mice, but not for larger animals like rats, due to the size of the imaging platform and the thicker skulls of larger rodents.

The team’s reliance on affordable and widely available equipment readily allows for replication and widespread adoption. According to the study senior author Jeffrey Iliff, Associate Director for Research at the VISN20 Mental Illness, Research, Education, and Clinical Center of the VA Puget Sound Health Care System and the Arthur J. and Marcella McCaffray Professor in Alzheimer’s Disease at the UW School of Medicine, “The glymphatic field is expanding rapidly, both in the clinical and pre-clinical realms. With so much work to do, we hope that this simple, low-cost approach will place rigorous study of glymphatic biology within the reach of a wider, more diverse group of research teams and institutions.”

Read the open access article by S.A. Keil et al., “Dynamic infrared imaging of cerebrospinal fluid tracer influx into the brain,” Neurophotonics 9(3) 031915 (2022), doi 10.1117/1.NPh.9.2.021915.

Journal: Neurophotonics
DOI: 10.1117/1.NPh.9.3.031915
Article Title: Dynamic infrared imaging of cerebrospinal fluid tracer influx into the brain
Article Publication Date: 17-May-2022

Media Contact

Daneet Steffens
SPIE–International Society for Optics and Photonics
daneets@spie.org
Office: 360-685-5478

Media Contact

Daneet Steffens
SPIE--International Society for Optics and Photonics

All latest news from the category: Medical Engineering

The development of medical equipment, products and technical procedures is characterized by high research and development costs in a variety of fields related to the study of human medicine.

innovations-report provides informative and stimulating reports and articles on topics ranging from imaging processes, cell and tissue techniques, optical techniques, implants, orthopedic aids, clinical and medical office equipment, dialysis systems and x-ray/radiation monitoring devices to endoscopy, ultrasound, surgical techniques, and dental materials.

Back to home

Comments (0)

Write a comment

Newest articles

Lighting up the future

New multidisciplinary research from the University of St Andrews could lead to more efficient televisions, computer screens and lighting. Researchers at the Organic Semiconductor Centre in the School of Physics and…

Researchers crack sugarcane’s complex genetic code

Sweet success: Scientists created a highly accurate reference genome for one of the most important modern crops and found a rare example of how genes confer disease resistance in plants….

Evolution of the most powerful ocean current on Earth

The Antarctic Circumpolar Current plays an important part in global overturning circulation, the exchange of heat and CO2 between the ocean and atmosphere, and the stability of Antarctica’s ice sheets….

Partners & Sponsors