GLP-1 and exendin derivatives in the diagnosis of diabetes mellitus and in the diagnosis and therapy of tumours

With the new GLP-1 and exendin-3 /-4 derivatives, as well as chimeric peptides from GLP-1 / exendin or exendin / GLP-1 respectively, peptides are available which are recognised and specifically bound by neuroendocrine GLP-1 expressing tumours, such as insulinomas, carcinoid tumours and small cell bronchial carcinomas. Consequently, a non-invasive specific evaluation of the lymph nodes and masses of the lungs by bronchial carcinomas is possible for the first time through a peptide. The new GLP-1 and exendin derivatives can be labelled in diverse ways with radioactive nuclides, fluorescent dyes, or MRI contrast agents and are applicable in the diagnosis and – through the binding of suitable radioactive emitters or chemotherapies -even in therapy of the tumours mentioned above (e.g. radiopeptide therapy and receptor-based chemotherapy). Primary tumours are not the only ones which can be specifically described and treated, but moreover also metastases (lymph nodes), which is of especially high interest in small cell bronchial carcinomas.

Furthermore the use of GLP-1 derivatives allows for the in vivo quantification of the ß-cell mass in the pancreas for the first time (namely the density of insulin producing cells) through external imaging, which opens completely new possibilities in the treatment and early diagnosis of diabetes mellitus. Even the response to medication in the treatment of diabetes mellitus is thereby measurable and thus an optimisation of the medical therapy combined with reduced costs is possible.

Further Information: PDF

TransMIT Gesellschaft für Technologietransfer mbH
Phone: +49 (0)641/943 64-12

Contact
Dr. Peter Stumpf

Media Contact

info@technologieallianz.de TechnologieAllianz e.V.

All latest news from the category: Technology Offerings

Back to home

Comments (0)

Write a comment

Newest articles

Superradiant atoms could push the boundaries of how precisely time can be measured

Superradiant atoms can help us measure time more precisely than ever. In a new study, researchers from the University of Copenhagen present a new method for measuring the time interval,…

Ion thermoelectric conversion devices for near room temperature

The electrode sheet of the thermoelectric device consists of ionic hydrogel, which is sandwiched between the electrodes to form, and the Prussian blue on the electrode undergoes a redox reaction…

Zap Energy achieves 37-million-degree temperatures in a compact device

New publication reports record electron temperatures for a small-scale, sheared-flow-stabilized Z-pinch fusion device. In the nine decades since humans first produced fusion reactions, only a few fusion technologies have demonstrated…

Partners & Sponsors