Method for Determining the Frequency Response of an Electrooptical Component

<strong>Background</strong><br>

Currently frequency analysis of optical signals relies on electrooptical modulators generating variable frequency signals. Subsequently, the response of the component due to the signal is detected and analysed. Therefore, complex calibration of the system is necessary. Additionally, the frequency range is confined to that of the electrooptical modulator.<br><br> <strong>Technology</strong><br> This invention provides a method for determining the frequency response of an electrooptical component, particularly, of a light-generating or light-modulating component. Optical pulses with a pulse frequency are generated. The electrooptical component is controlled by an electrical measuring signal with a measuring frequency in such a manner that an optical output signal is formed that is modulated with the measuring frequency. The measuring frequency is equal to an integral multiple of the pulse frequency plus a predetermined frequency offset. The pulses and the output signal are mixed, and a mixed product is detected whose modulation frequency corresponds to the predetermined frequency offset. The mixed product indicates the frequency response of the electrooptical component at the measuring frequency.<br><br> <p><strong>Benefits</strong><br> <ul> <li>Frequency response of the system can be measured easily by autocorrelation</li> <li>No complex calibration of the measuring system is necessary</li> </ul> <p><strong>IP Rights</strong><br> German Patent DE 10346379<br> US Patent US 7 522 285 <br> <br> <strong>Origin</strong><br> Technische Universität Berlin, Germany</p>

Further Information: PDF

ipal GmbH
Phone: +49 (0)30/2125-4820

Contact
Dr. Dirk Dantz

Media Contact

info@technologieallianz.de TechnologieAllianz e.V.

All latest news from the category: Technology Offerings

Back to home

Comments (0)

Write a comment

Newest articles

High-energy-density aqueous battery based on halogen multi-electron transfer

Traditional non-aqueous lithium-ion batteries have a high energy density, but their safety is compromised due to the flammable organic electrolytes they utilize. Aqueous batteries use water as the solvent for…

First-ever combined heart pump and pig kidney transplant

…gives new hope to patient with terminal illness. Surgeons at NYU Langone Health performed the first-ever combined mechanical heart pump and gene-edited pig kidney transplant surgery in a 54-year-old woman…

Biophysics: Testing how well biomarkers work

LMU researchers have developed a method to determine how reliably target proteins can be labeled using super-resolution fluorescence microscopy. Modern microscopy techniques make it possible to examine the inner workings…

Partners & Sponsors