Handling Robot SAMARA

The handling robot system SAMARA (System Applying Momentum transmission for Acceleration of an end-effector with Redundant Axis) combines the advantages of heavy payloads and wide working space from Scara robots with the high acceleration of Delta robots. This is achieved by a new motion sequence that is characterized by a steadily rotation of the first axis. Thus it is necessary to accelerate only small masses, as the main part of energy used for the motion cycle is kept for the following cycle.<br><br>By applying such a redundant axis the kinetic energy can be retained in the robot links during a picking process and returned to the effector for speeding up the whole robot additional to the drives torques. As the nullspace movement ends with a stretched second and third link, acceleration of the effector must be regarded as an impulse, leading to acceleration of 20g. <br>

SAMARA allows solving “pick and place“ tasks even for heavy loads extremely fast, precise and energy-beneficial with only little space required for the SAMARA robot itself.<br> <br> <strong>Benefits</strong><br> <ul> <li>Under actuated motion</li> <li>Highly dynamic operation of multiple arms within same work space</li> <li>Suitable for heavy payloads</li> <li>Wide working space</li> <li>High acceleration (up to 20g)</li> <li>Only low space required</li> <li>Flexible and very precise</li> <li>Combination of various end-effectors possible</li> <li>Continuous movement reduces energy loss caused by stopping and change of direction</li> </ul><br> <strong>IP Rights</strong><br> German Patent Application <br> <br> <strong>Patent Owner</strong><br> Technische Universität Berlin<br>

Further Information: PDF

ipal GmbH
Phone: +49 (0)30/2125-4820

Contact
Dr. Dirk Dantz

Media Contact

info@technologieallianz.de TechnologieAllianz e.V.

All latest news from the category: Technology Offerings

Back to home

Comments (0)

Write a comment

Newest articles

Superradiant atoms could push the boundaries of how precisely time can be measured

Superradiant atoms can help us measure time more precisely than ever. In a new study, researchers from the University of Copenhagen present a new method for measuring the time interval,…

Ion thermoelectric conversion devices for near room temperature

The electrode sheet of the thermoelectric device consists of ionic hydrogel, which is sandwiched between the electrodes to form, and the Prussian blue on the electrode undergoes a redox reaction…

Zap Energy achieves 37-million-degree temperatures in a compact device

New publication reports record electron temperatures for a small-scale, sheared-flow-stabilized Z-pinch fusion device. In the nine decades since humans first produced fusion reactions, only a few fusion technologies have demonstrated…

Partners & Sponsors