Precise temperature measurements with invisible light

10.05.2019

Novel infrared thermometer offers dramatically improved performance

Ordinarily, you won't encounter a radiation thermometer until somebody puts one in your ear at the doctor's office or you point one at your forehead when you're feeling feverish.


Operation of the NIST Ambient Radiation Thermometer, which is approximately 60 cm (24 in.) long: (1) Infrared (IR) light from a fixed-temperature calibrated source (at right, not shown) enters the thermometer enclosure through this lens, which focuses the radiation onto a "field stop," analogous to the f-stop aperture in photography. (2) A circular metal chopper slices the IR beam into a sequence of pulses. (3) The first lens inside the central cylinder converts the light from the field stop to a parallel beam. (4) The light passes through this insulated cylinder about 30 cm (12 in.) long, which is temperature-controlled by a feedback system. Stray radiation is blocked by another stop. (5) A second lens focuses the light onto a pyroelectric detector. (6) The detector output is routed to an amplifier that boosts the signal to readily readable levels.

Credit: NIST

But more sophisticated and highly calibrated research-grade "non-contact" thermometers--which measure the infrared (heat) radiation given off by objects without touching them--are critically important to many endeavors besides health care.

However, even high-end conventional radiation thermometers have produced readings with worryingly large uncertainties. But now researchers at the National Institute of Standards and Technology (NIST) have invented a portable, remarkably stable standards-quality radiation thermometer about 60 centimeters (24 inches) long that is capable of measuring temperatures to a precision of within a few thousandths of a degree Celsius.

NIST has a long history of studying radiation thermometers. The new prototype instrument, which builds on that work, can measure temperatures between -50 C (-58 F) to 150 C (302 F). The corresponding infrared wavelengths are from 8 to 14 micrometers (millionths of a meter), which is a sort of thermodynamic sweet spot.

"All temperatures are equal, but some are more equal than others," said NIST physicist Howard Yoon, who created the thermometer design and directed the project, described in the journal Optics Express. "That 200-degree span covers nearly all naturally occurring temperatures on Earth. If you make a big impact in measuring objects in that range, it really matters."

In addition to clinical medicine, temperatures in that region are of urgent importance in applications where contact is not appropriate or feasible. For example, surgeons need to measure the temperature of organs prior to transplant.

Modern farmers need accurate temperatures when handling, storing and processing food. Satellites require non-contact thermometers for measuring temperatures on land and the surface of the sea.

Conventional radiation thermometers often contain little more than a lens for focusing the infrared radiation and a pyroelectric sensor, a device that converts heat energy into an electrical signal. Their measurements can be affected by temperature differences along the thermometer and by temperature outside the instrument.

The NIST design, called the Ambient-Radiation Thermometer (ART), is fitted with a suite of interior thermometers that constantly gauge temperatures at different points in the instrument.

Those readings are sent to a feedback loop system which keeps the 30-cm (12-inch) cylinder containing the detector assembly at a constant temperature of 23 C (72 F).

It also features other design improvements, including a method for reducing errors from what is called the size-of-source effect, which results when radiation enters the instrument from areas outside its specified field of view.

The ART's major advantage is its unprecedented stability. After it has been calibrated against standards-grade contact thermometers, the instrument can remain stable to within a few thousandths of a degree for months under continuous operation. That makes the system very promising for applications that involve remote sensing over long periods.

"Imagine being able to take the NIST design out in the field as traveling radiation thermometers for accurately measuring variables such as land- and sea-surface temperatures," Yoon said. "It could serve as a trustworthy method of calibrating satellite IR sensors and validating the huge weather science programs that are used to predict, for example, the paths and strengths of hurricanes." Its lower range of -50 C (-58 F) makes it suitable for monitoring the temperature of ice over polar regions, typically in the range of -40 C (-40 F) to -10 C (14 F).

There are several methods of making very high-accuracy temperature measurements, but few are well-suited to field work. Platinum resistance thermometers are fragile and need frequent recalibration. The standard temperature source for transferring that calibration to the ART involves a heat-source cavity inside about 42 liters (11 gallons) of liquid.

"Those are the best sources we have," Yoon said. "But it is impractical to measure water temperature by putting a thermometer in the ocean at intervals, and you don't want to constantly calibrate your radiation thermometer using a calibration source like that on board a ship."

Gerald Fraser, chief of NIST's Sensor Science Division, said that "Yoon's innovation makes non-contact thermometry competitive with the best commercial contact thermometers in accuracy and stability in a temperature range that humans experience daily. This enables many new opportunities in product inspection and quality control and in defense and security where conventional contact methods are impractical or too expensive."

###

Paper: H.W. Yoon, V. Khromchenko and G.P. Eppeldauer, Improvements in the design of thermal-infrared radiation thermometers and sensors. Optics Express. Published in May 13, 2019 issue. DOI: https://doi.org/10.1364/OE.27.014246

Media Contact

Ben P. Stein
benjamin.stein@nist.gov
301-975-2763

 @usnistgov

http://www.nist.gov 

Ben P. Stein | EurekAlert!
Further information:
https://www.nist.gov/news-events/news/2019/05/precise-temperature-measurements-invisible-light
http://dx.doi.org/10.1364/OE.27.014246

More articles from Physics and Astronomy:

nachricht Computing faster with quasi-particles
10.05.2019 | Julius-Maximilians-Universität Würzburg

nachricht A new filter to better map the dark universe
09.05.2019 | DOE/Lawrence Berkeley National Laboratory

All articles from Physics and Astronomy >>>

The most recent press releases about innovation >>>

Die letzten 5 Focus-News des innovations-reports im Überblick:

Im Focus: Researchers take a step towards light-based, brain-like computing chip

Researchers from the Universities of Münster (Germany), Oxford and Exeter (both UK) have succeeded in developing a piece of hardware which could pave the way for creating computers which resemble the human brain. The scientists produced a chip containing a network of artificial neurons that works with light and can imitate the behaviour of neurons and their synapses. The network is able to “learn” information and use this as a basis for computing and recognizing patterns. As the system functions solely with light and not with electrons, it can process data many times faster than traditional systems. The study is published in “Nature”.

A technology that functions like a brain? In these times of artificial intelligence, this no longer seems so far-fetched - for example, when a mobile phone can...

Im Focus: First demonstration of antimatter wave interferometry

An international collaboration with participation of the University of Bern has demonstrated for the first time in an interference experiment that antimatter particles also behave as waves besides having particle properties. This success paves the way to a new field of investigations of antimatter.

Matter waves constitute a crucial feature of quantum mechanics, where particles have wave properties in addition to particle characteristics. This...

Im Focus: Quantum sensor for photons

A photodetector converts light into an electrical signal, causing the light to be lost. Researchers led by Tracy Northup at the University of Innsbruck have now built a quantum sensor that can measure light particles non-destructively. It can be used to further investigate the quantum properties of light.

Physicist Tracy Northup is currently researching the development of quantum internet at the University of Innsbruck. The American citizen builds interfaces...

Im Focus: RadarGlass: Functional thin-film structures for integrated radar sensors

It is only an inconspicuous piece of paper, but it is an important milestone for autonomous driving: At the end of 2018 the three partners from the joint research project RadarGlass applied for a patent for an innovative radar system. The Fraunhofer Institute for Laser Technology ILT from Aachen, the Fraunhofer Institute for Organic Electronics, Electron Beam and Plasma Technology FEP from Dresden and the Institute of High Frequency Technology IHF of RWTH Aachen University have developed a coating process chain that enables radar sensors to be integrated in car headlights. After almost two years in development they have manufactured a working prototype.

Completely autonomous vehicles pose an enormous challenge for sensor technology because, in principle, the supporting system must hear, see and feel better...

Im Focus: Novel method developed by HKBU scholars could help produce purer, safer drugs

Physics and Chemistry scholars from Hong Kong Baptist University (HKBU) have invented a new method which could speed up the drug discovery process and lead to the production of higher quality medicinal drugs which are purer and have no side effects. The technique, which is a world-first breakthrough, uses a specific nanomaterial layer to detect the target molecules in pharmaceuticals and pesticides in just five minutes.

The new HKBU invention can be applied to the drug discovery process, as well as the production and quality control stages of pharmaceutical manufacturing. It...

All Focus news of the innovation-report >>>

Anzeige

Anzeige

VideoLinks
Industry & Economy
Event News

SEMANTiCS 2019 brings together industry leaders and data scientists in Karlsruhe

29.04.2019 | Event News

Revered mathematicians and computer scientists converge with 200 young researchers in Heidelberg!

17.04.2019 | Event News

First dust conference in the Central Asian part of the earth’s dust belt

15.04.2019 | Event News

 
Latest News

Serotonin boosts neuronal powerplants protecting against stress

10.05.2019 | Life Sciences

Copper oxide photocathodes: laser experiment reveals location of efficiency loss

10.05.2019 | Process Engineering

Hummingbird robot uses AI to soon go where drones can't

10.05.2019 | Information Technology

VideoLinks
Science & Research
Overview of more VideoLinks >>>