New urine test detects common cause of kidney transplant failure

A new and simple urine test can detect polyomavirus nephropathy, a relatively new and serious complication that affects up to 9% of kidney transplant recipients, according to a study appearing in the February 2009 issue of the Journal of the American Society Nephrology (JASN). The advance could lead to better diagnosis and treatment of patients with this condition.

While polyomaviruses are normally occurring viruses that harmlessly infect many adults, they can pose serious health problems for individuals who become immunocompromised. Such is the case for many kidney transplant recipients who must take immunosuppressive medications to safeguard against organ rejection. Some of these patients develop a damaging condition called polyomavirus nephropathy that can lead to chronic kidney failure and the need to re-initiate dialysis or undergo another transplant.

Because there are no effective therapies to treat polyomavirus nephropathy, it is important to diagnose the condition as early as possible, before it becomes serious. Therapy normally consists of lowering the dose of immunosuppressive drugs and hoping for natural viral clearance.

Unfortunately, there currently is no definitive way to accurately diagnose polyomavirus nephropathy. Physicians rely mostly on invasive and expensive kidney biopsies, which sometimes give false negative results. But now Volker Nickeleit, MD, of the University of North Carolina in Chapel Hill, North Carolina and his colleagues have discovered a new and noninvasive way to test for the condition. The test measures “Haufen”—a German term meaning stack or pile—in the urine. Haufen are tightly clustered viral aggregates that form within the kidneys in patients with polyomavirus nephropathy and are excreted in the urine. Testing for Haufen is fast (three hours), inexpensive (less than $400), and easy to perform with current laboratory equipment.

Through their investigation, the researchers found Haufen in urine samples from all 21 patients with early or late stages of polyomavirus nephropathy, but not in any of the 139 individuals without the condition.

According to Dr. Nickeleit, the new test could help physicians identify and monitor patients with polyomavirus nephropathy and could guide them as they design new therapeutic strategies. “An early and accurate diagnosis of polyomavirus nephropathy will result in a better understanding of the disease and ultimately improve treatment,” he said. “Our diagnostic test is unique and could have a tremendous clinical impact,” he added.

While their findings look promising, the authors stress that additional studies—particularly large prospective clinical trials—are needed to verify the test's potential before it can become available for widespread use in patients with suspected polyomavirus nephropathy.

The article, entitled “A New Urinary Biomarker to Accurately Predict Polyomavirus Nephropathy,” will appear online at http://jasn.asnjournals.org/ on January 21, 2009, and in the February 2009 print issue of JASN.

Media Contact

Shari Leventhal EurekAlert!

More Information:

http://www.asn-online.org

All latest news from the category: Health and Medicine

This subject area encompasses research and studies in the field of human medicine.

Among the wide-ranging list of topics covered here are anesthesiology, anatomy, surgery, human genetics, hygiene and environmental medicine, internal medicine, neurology, pharmacology, physiology, urology and dental medicine.

Back to home

Comments (0)

Write a comment

Newest articles

Superradiant atoms could push the boundaries of how precisely time can be measured

Superradiant atoms can help us measure time more precisely than ever. In a new study, researchers from the University of Copenhagen present a new method for measuring the time interval,…

Ion thermoelectric conversion devices for near room temperature

The electrode sheet of the thermoelectric device consists of ionic hydrogel, which is sandwiched between the electrodes to form, and the Prussian blue on the electrode undergoes a redox reaction…

Zap Energy achieves 37-million-degree temperatures in a compact device

New publication reports record electron temperatures for a small-scale, sheared-flow-stabilized Z-pinch fusion device. In the nine decades since humans first produced fusion reactions, only a few fusion technologies have demonstrated…

Partners & Sponsors