What’s the best way to assess lower limb peripheral arterial disease?

Peripheral arterial disease (PAD) can cause pain on walking and ischaemia resulting in pain when resting, ulceration and gangrene.

One in five people over the age of 65 is thought to have PAD. Risk factors for PAD include smoking, hypertension and diabetes. It is vital that the severity of the disease is accurately assessed as the best choice of treatment depends on how advanced the disease is.

Contrast angiography, the reference standard diagnostic test, is associated with adverse events related to arterial puncture, ionising radiation, and the injection of contrast agents needed to produce the images. Other imaging tests are available and include ultrasound, magnetic resonance and computed tomography (CT) angiography scans.

This systematic review assessed the research literature on the diagnostic accuracy of these different imaging techniques. When comparing the different tests, the review found that magnetic resonance angiography had the best overall diagnostic accuracy, and is generally preferred by patients over conventional contrast angiography.

However, it was not possible to compare the tests based on which gave patients the best outcomes as there was too little research available that measured this aspect.

Further information can be obtained from Alison Booth, Tel: 01904 321048; email: ab42@york.ac.uk

Media Contact

Alison Booth alfa

All latest news from the category: Health and Medicine

This subject area encompasses research and studies in the field of human medicine.

Among the wide-ranging list of topics covered here are anesthesiology, anatomy, surgery, human genetics, hygiene and environmental medicine, internal medicine, neurology, pharmacology, physiology, urology and dental medicine.

Back to home

Comments (0)

Write a comment

Newest articles

Superradiant atoms could push the boundaries of how precisely time can be measured

Superradiant atoms can help us measure time more precisely than ever. In a new study, researchers from the University of Copenhagen present a new method for measuring the time interval,…

Ion thermoelectric conversion devices for near room temperature

The electrode sheet of the thermoelectric device consists of ionic hydrogel, which is sandwiched between the electrodes to form, and the Prussian blue on the electrode undergoes a redox reaction…

Zap Energy achieves 37-million-degree temperatures in a compact device

New publication reports record electron temperatures for a small-scale, sheared-flow-stabilized Z-pinch fusion device. In the nine decades since humans first produced fusion reactions, only a few fusion technologies have demonstrated…

Partners & Sponsors