MDCT is Better Than Plain Film in Diagnosing Hip Replacement Complications

Multidetector CT (MDCT) is superior to plain film x-rays for detecting problems that occur in patients who have undergone hip replacements, a new study shows.

Hip prostheses generally last 10-15 years, said Joshua Farber, MD, vice chair of clinical affairs at Indiana University Hospital in Indianapolis. Then a series of complications can occur. Dr. Farber studied 45 patients who had pain in their replaced hip, using both plain film x-rays and MDCT to diagnose the problem. MDCT was 100% accurate in detecting bone loss near the prosthesis, said Dr. Farber. That compares to a 67% accuracy rate for plain films. MDCT had an added benefit for these patients, in that it could pinpoint exactly where the bone loss had occurred so the surgeon could more easily repair the problem, said Dr. Farber.

MDCT was 100% accurate in detecting fractures near the prosthesis, compared to 94% for plain films. In addition, MDCT was 61% accurate in detecting whether the prosthesis had come loose, compared to 54% for plain films. The ability to diagnose acetabular component loosening on MDCT was influenced by the experience of the radiologists reading the examination, said Dr. Farber. “When the most experienced radiologist read the examination, the accuracy rate was 72%.”

Dr. Farber noted that they are currently comparing MDCT to plain film to determine which is a better test for diagnosing wear on the plastic liner between the metal components of the prosthesis and particle disease (as the prosthesis wears down, particles get into the tissues near the prosthesis and can cause an inflammation).

“As the population ages, we are seeing more of these types of patients. The increase in obesity also plays a role in the increase in hip replacements,” Dr. Farber said. “At my institution we now do MDCT examinations on a majority of these patients. We recommend that, at the very least, MDCT should be performed if a patient has a plain film X-ray and the X-ray is questionable. MDCT also should be performed if surgery is needed since it provides a much better guide than plain film for the surgeon,” Dr. Farber said.

The study will be presented on May 5 at the American Roentgen Ray Society Annual Meeting in Miami Beach, FL.

Media Contact

Keri J. Sperry ARRS

All latest news from the category: Health and Medicine

This subject area encompasses research and studies in the field of human medicine.

Among the wide-ranging list of topics covered here are anesthesiology, anatomy, surgery, human genetics, hygiene and environmental medicine, internal medicine, neurology, pharmacology, physiology, urology and dental medicine.

Back to home

Comments (0)

Write a comment

Newest articles

High-energy-density aqueous battery based on halogen multi-electron transfer

Traditional non-aqueous lithium-ion batteries have a high energy density, but their safety is compromised due to the flammable organic electrolytes they utilize. Aqueous batteries use water as the solvent for…

First-ever combined heart pump and pig kidney transplant

…gives new hope to patient with terminal illness. Surgeons at NYU Langone Health performed the first-ever combined mechanical heart pump and gene-edited pig kidney transplant surgery in a 54-year-old woman…

Biophysics: Testing how well biomarkers work

LMU researchers have developed a method to determine how reliably target proteins can be labeled using super-resolution fluorescence microscopy. Modern microscopy techniques make it possible to examine the inner workings…

Partners & Sponsors