NIST Quantifies Low Levels of ‘Heart Attack Risk’ Protein

C-reactive protein (CRP), a molecule produced by the liver in response to inflammation, normally accounts for less than 1/60,000 of a person’s total serum protein, or about 1 milligram per liter (mg/L) of serum.

Recent evidence suggests that a CRP level between 1 and 3 mg/L indicates a moderate risk of cardiovascular disease while a level greater than 3 mg/L predicts a high risk. A clinical diagnostic procedure known as the high-sensitivity CRP (hsCRP) test has been used to detect higher-than-normal levels of the protein and warn a patient about elevated risk for cardiovascular disease.

However, there is no certified reference material—in this case, a sample of human serum with accurately determined amounts of the CRP for various risk levels—against which the accuracy of methods for measuring CRP can be evaluated. The problem: normal, low-risk of cardiovascular disease CRP levels are so low that even mass spectrometry (a very sensitive technique for separating and identifying molecules based on mass) cannot easily quantify them.

In a recent paper in Analytical Chemistry,* NIST researchers Eric Kilpatrick and David Bunk describe the first steps toward development of a certified reference material that can be used to assess the accuracy of routine clinical laboratory tests for CRP. The researchers accomplished this by isolating the minute amounts (less than 1 mg/L) of CRP circulating at normal levels in serum prior to measurement. Using a protein isolation technique called affinity purification, Kilpatrick and Bunk added polystyrene beads coated with anti-CRP antibodies to normal human serum. The antibodies bind tightly to any circulating CRP, allowing it to be easily removed from solution. The researchers then cleave the purified protein they isolated into its component parts, known as peptides, using enzyme digestion. The peptides are more readily measured by the mass spectrometer, resulting in a very precise determination of the total CRP.

To see if their purification method yields CRP that can serve as a reference material, Kilpatrick and Bunk will next mix purified CRP with genetically engineered CRP containing a heavy isotope of nitrogen (15N) and then run the combined pool through affinity purification, enzyme digestion and mass spectrometry. The peptides with the heavy 15N atoms will be easily detected and precisely quantified by the mass spectrometer. If the measurements for the 15N-tagged peptides compare favorably to those made for the purified serum CRP, then that will validate the use of the affinity purification method for quantifying extremely low levels of the protein. In turn, this validation will clear the way for purified serum CRP derived by the NIST method to be eventually used as a quality control and calibration tool by manufacturers for the hsCRP test.

Media Contact

Michael E. Newman Newswise Science News

More Information:

http://www.nist.gov

All latest news from the category: Life Sciences and Chemistry

Articles and reports from the Life Sciences and chemistry area deal with applied and basic research into modern biology, chemistry and human medicine.

Valuable information can be found on a range of life sciences fields including bacteriology, biochemistry, bionics, bioinformatics, biophysics, biotechnology, genetics, geobotany, human biology, marine biology, microbiology, molecular biology, cellular biology, zoology, bioinorganic chemistry, microchemistry and environmental chemistry.

Back to home

Comments (0)

Write a comment

Newest articles

Superradiant atoms could push the boundaries of how precisely time can be measured

Superradiant atoms can help us measure time more precisely than ever. In a new study, researchers from the University of Copenhagen present a new method for measuring the time interval,…

Ion thermoelectric conversion devices for near room temperature

The electrode sheet of the thermoelectric device consists of ionic hydrogel, which is sandwiched between the electrodes to form, and the Prussian blue on the electrode undergoes a redox reaction…

Zap Energy achieves 37-million-degree temperatures in a compact device

New publication reports record electron temperatures for a small-scale, sheared-flow-stabilized Z-pinch fusion device. In the nine decades since humans first produced fusion reactions, only a few fusion technologies have demonstrated…

Partners & Sponsors