Forum for Science, Industry and Business

Sponsored by:     3M 
Search our Site:

 

Robot arms with the flexibility of an elephant’s trunk

18.03.2019

Unlike conventional robot arms with their hinged and swivel joints, the flexible arms being developed by Professor Stefan Seelecke and his research group at Saarland University are constructed using muscles made from shape-memory wires that have the ability to bend in almost any direction and to wind themselves around corners. The flexible arms are powered electrically and so can do without the usual pneumatic equipment or other bulky accessories. As the shape-memory alloy itself has sensor properties, the arms can be controlled without the need for additional sensors.

The new technology can be used to build large robotic arms with the flexibility of an elephant’s trunk or ultrafine tentacles for use in endoscopic operations.


Dominik Scholtes (l.), Rouven Britz and Yannik Goergen (r.), doctoral research students in Professor Seelecke´s team, with prototypes of the flexible robot arms.

Credit: Oliver Dietze


Prof. Dr. Stefan Seelecke

Credit: Oliver Dietze

From the 1st to the 5th of April, the research team will be at Hannover Messe, where they will be using prototypes to demonstrate the capabilities of the shape memory arms at the Saarland Research and Innovation Stand (Hall 2, Stand B46). Seelecke’s team is looking for partners interested in developing the technology for practical applications.

Human arm or robotic arm – there are limits to the flexibility of both types of limb. The joints are often rather bulky and connect rigid bones or mechanical assemblies. Motion is typically restricted to certain spatial directions. In contrast, an elephant’s trunk or an octopus’s tentacle offer far greater agility.

The presence of tens of thousands of muscles enables these creatures to move the trunk or tentacle in all directions, to bend it to just the right degree and to grip things with great power. The engineers at Saarland University have drawn inspiration from these natural models. They are developing robotic arms that do away with the need for joints or rigid skeletons or frameworks, creating structures that are both lightweight and extremely supple.

Professor Stefan Seelecke and his team are collaborating with researchers from Darmstadt Technical University on a project funded by the German Research Foundation (DFG) in which they are developing thin, precisely controlled artificial tentacles. In future, the system could find use as a guide wire in cardiac surgery or as an endoscope in gastroscopic and colonoscopic procedures.

The researchers are therefore equipping the artificial tentacles with additional functions such as a gripper or a tip with adjustable stiffness that delivers an improved pushing force. But the technology can also be scaled up successfully to produce large robotic arms not dissimilar to an elephant’s trunk.

The flexibility of these new robotic arms comes from the artificial ‘muscles’ used by the Saarbrücken research team. These muscles are composed of ultrafine nickel-titanium (nitinol) wires that are able to contract and lengthen in a controlled manner. The ultrafine nitinol wires contract like real muscles, depending on whether an electric current is flowing or not.

‘Nickel-titanium is what is known as a “shape memory” alloy, which means that it is able to “remember” its shape and to return to that original shape after it being deformed. If an electric current flows through a nitinol wire, the material heats up, causing it to adopt a different crystal structure with the result that the wire becomes shorter. If the current is switched off, the wire cools down and lengthens again,’ explains Professor Seelecke.

His team at the Intelligent Material Systems Lab at Saarland University create bundles of these wires that act as artificial muscle fibres. ‘Multiple ultrathin wires provide a large surface area through which they can transfer heat, which means they contract more rapidly. The wires have the highest energy density of all known drive mechanisms. And they can exert a very high tensile force over a short distance,’ explains Seelecke, who also conducts research at ZeMA – the Center for Mechatronics and Automation Technology in Saarbrücken. The research team at ZeMA is developing a range of applications for these wires, from novel cooling systems to new types of valves and pumps.

For the robot arms, the researchers link the wire bundles so that they act as flexor or extensor muscles, which when they work in concert produce a flowing motion. ‘The tentacles that could be used in future as medical catheters or in endoscopic procedures have diameters of only around 300 to 400 micrometres. No other drive system is of comparable size. Previous systems used for catheter procedures were significantly larger and this tended to limit their capabilities,’ explains Paul Motzki, who wrote his doctoral thesis on the shape memory wires and is a research assistant in Professor Seelecke’s group.

The new tentacles can be very precisely controlled and can be used to create multifunctional tools. For example, the distal tip of the tentacle can be made to perform a pushing movement. The exact pattern of movement required is modelled by the researchers and then programmed on a semiconductor chip. And the system has no need for other sensors. The wires themselves provide all the necessary data. ‘The material from which the wires are made has sensory properties. The controller unit is able to interpret the electrical resistance data so that it knows the exact position and orientation of the wires at any one time,’ says Paul Motzki.

Unlike conventional robotic arms that require power from an electric motor or from a pneumatic or hydraulic system, the arms being developed in Saarbrücken have no need for any such heavy equipment. All the wires need is electric current. ‘This makes the system light, highly adaptable and quiet to operate, and it means that production costs are relatively low, says Professor Seelecke. The research team will be exhibiting their system prototypes at Hannover Messe and will be demonstrating the potential of these novel continuum robotic arms.

More Press photographs are available at https://www.uni-saarland.de/universitaet/aktuell/pm/pressefotos.html and may be used free of charge.

This press release is available in German at:
https://www.uni-saarland.de/nc/universitaet/aktuell/artikel/nr/20605.html

Contact for press enquiries:
Prof. Dr. Stefan Seelecke, Intelligent Material Systems Lab, Saarland University:
Tel.: +49 681 302-71341; Email: stefan.seelecke@imsl.uni-saarland.de
Dr. Paul Motzki, Tel.: +49 (0)6841 85787-545; Email: p.motzki@zema.de

Background:
Professor Stefan Seelecke and his research team at the Intelligent Material Systems Lab at Saarland University and ZeMA (Center for Mechatronics and Automation Technology) in Saarbrücken are exploiting the properties of the shape memory alloy nickel-titanium in a wide range of technical applications.

ZeMA – Center for Mechatronics and Automation Technology in Saarbrücken is a research hub for collaborative projects involving researchers from Saarland University, Saarland University of Applied Sciences (htw saar) and industrial partners. ZeMA is home to a large number of industry-specific development projects that aim to transform research findings into practical industrial applications. http://www.zema.de/

Wissenschaftliche Ansprechpartner:

Prof. Dr. Stefan Seelecke, Intelligent Material Systems Lab, Saarland University:
Tel.: +49 681 302-71341; Email: stefan.seelecke@imsl.uni-saarland.de
Dr. Paul Motzki, Tel.: +49 (0)6841 85787-545; Email: p.motzki@zema.de

Claudia Ehrlich | Universität des Saarlandes

Further reports about: Automation ZeMA artificial elephant’s trunk muscles shape memory tentacle

More articles from Power and Electrical Engineering:

nachricht A miniature stretchable pump for the next generation of soft robots
15.08.2019 | Ecole Polytechnique Fédérale de Lausanne

nachricht Vehicle Emissions: New sensor technology to improve air quality in cities
13.08.2019 | Technische Universität Graz

All articles from Power and Electrical Engineering >>>

The most recent press releases about innovation >>>

Die letzten 5 Focus-News des innovations-reports im Überblick:

Im Focus: A miniature stretchable pump for the next generation of soft robots

Soft robots have a distinct advantage over their rigid forebears: they can adapt to complex environments, handle fragile objects and interact safely with humans. Made from silicone, rubber or other stretchable polymers, they are ideal for use in rehabilitation exoskeletons and robotic clothing. Soft bio-inspired robots could one day be deployed to explore remote or dangerous environments.

Most soft robots are actuated by rigid, noisy pumps that push fluids into the machines' moving parts. Because they are connected to these bulky pumps by tubes,...

Im Focus: Vehicle Emissions: New sensor technology to improve air quality in cities

Researchers at TU Graz are working together with European partners on new possibilities of measuring vehicle emissions.

Today, air pollution is one of the biggest challenges facing European cities. As part of the Horizon 2020 research project CARES (City Air Remote Emission...

Im Focus: Self healing robots that "feel pain"

Over the next three years, researchers from the Vrije Universiteit Brussel, University of Cambridge, École Supérieure de Physique et de Chimie Industrielles de la ville de Paris (ESPCI-Paris) and Empa will be working together with the Dutch Polymer manufacturer SupraPolix on the next generation of robots: (soft) robots that ‘feel pain’ and heal themselves. The partners can count on 3 million Euro in support from the European Commission.

Soon robots will not only be found in factories and laboratories, but will be assisting us in our immediate environment. They will help us in the household, to...

Im Focus: Scientists create the world's thinnest gold

Scientists at the University of Leeds have created a new form of gold which is just two atoms thick - the thinnest unsupported gold ever created.

The researchers measured the thickness of the gold to be 0.47 nanometres - that is one million times thinner than a human finger nail. The material is regarded...

Im Focus: Study on attosecond timescale casts new light on electron dynamics in transition metals

An international team of scientists involving the Max Planck Institute for the Structure and Dynamics of Matter (MPSD) in Hamburg has unraveled the light-induced electron-localization dynamics in transition metals at the attosecond timescale. The team investigated for the first time the many-body electron dynamics in transition metals before thermalization sets in. Their work has now appeared in Nature Physics.

The researchers from ETH Zurich (Switzerland), the MPSD (Germany), the Center for Computational Sciences of University of Tsukuba (Japan) and the Center for...

All Focus news of the innovation-report >>>

Anzeige

Anzeige

VideoLinks
Industry & Economy
Event News

The power of thought – the key to success: CYBATHLON BCI Series 2019

16.08.2019 | Event News

4th Hybrid Materials and Structures 2020 28 - 29 April 2020, Karlsruhe, Germany

14.08.2019 | Event News

What will the digital city of the future look like? City Science Summit on 1st and 2nd October 2019 in Hamburg

12.08.2019 | Event News

 
Latest News

Working out why plants get sick

16.08.2019 | Life Sciences

Newfound superconductor material could be the 'silicon of quantum computers'

16.08.2019 | Physics and Astronomy

Stanford develops wireless sensors that stick to the skin to track our health

16.08.2019 | Medical Engineering

VideoLinks
Science & Research
Overview of more VideoLinks >>>