Detecting Pathogens in Waterways: An Improved Approach

RS is USDA's principal intramural scientific research agency, and this research supports the USDA priority of ensuring food safety.

When health officials test a public beach or lake for Salmonella or E. coli 0157:H7, they use two types of non-pathogenic bacteria, Enterococci and generic E. coli, as indicators. But while the indicators are often detected in contaminated waterways, their abundance doesn't guarantee the presence of either pathogen, according to Michael Jenkins, a microbiologist at the ARS J. Phil Campbell Sr. Natural Resource Conservation Center in Watkinsville, Ga.

These indicator organisms are often reliable, but investigators have detected the indicators in pathogen-free waters and have failed to find them in waters that contained sufficient levels of the pathogens to make someone sick.

The indicators are used as signals because both pathogens are hard to detect directly at levels that will make someone ill: just 100 cells of Salmonella and just 10 to 100 cells of E. coli 0157:H7, the toxic strain of the bacterium. Organic matter in a water sample will throw off current PCR (polymerase chain reaction) technology when it is used as a tool for detection. Salmonella and E. coli outbreaks are often attributed to agricultural operations, so improving ways to track down sources of outbreaks is a major priority.

Jenkins and his ARS colleagues Dinku Endale and Dwight Fisher at Watkinsville combined techniques previously developed to assess water quality and detect pathogens in laboratory settings: a water filtration technique to concentrate the pathogens; a special medium for growing and measuring the number of pathogenic cells; a biochemical testing process; and PCR technology.

They collected water samples from a pond at the Watkinsville site, ran them through a special filter, removed the filter contents and used a centrifuge to spin the filtered contents into a pellet form. They used the suspended pellets to develop cell cultures, confirmed their identity with a genetic method, and determined the concentration found in the original samples.

Their results, published in the Journal of Applied Microbiology, showed the process can be used to detect just a few cells of pathogenic E. coli and Salmonella in a 10-liter water sample, lower levels than any previously detected. Because the system involves collecting cell cultures, it also may lead to developing culture collections that-like a fingerprint database-could be used to identify bacterial strains that are potential sources of future outbreaks.

Read more about this research in the February 2011 issue of Agricultural Research magazine.

Media Contact

Dennis O'Brien EurekAlert!

All latest news from the category: Agricultural and Forestry Science

Back to home

Comments (0)

Write a comment

Newest articles

Superradiant atoms could push the boundaries of how precisely time can be measured

Superradiant atoms can help us measure time more precisely than ever. In a new study, researchers from the University of Copenhagen present a new method for measuring the time interval,…

Ion thermoelectric conversion devices for near room temperature

The electrode sheet of the thermoelectric device consists of ionic hydrogel, which is sandwiched between the electrodes to form, and the Prussian blue on the electrode undergoes a redox reaction…

Zap Energy achieves 37-million-degree temperatures in a compact device

New publication reports record electron temperatures for a small-scale, sheared-flow-stabilized Z-pinch fusion device. In the nine decades since humans first produced fusion reactions, only a few fusion technologies have demonstrated…

Partners & Sponsors