Detecting small amounts of virus in early infections

High-pressure preconcentration devices for increasing the potency of biofluid samples to be used with point-of-care assays for detection of pathogens, such as flu or coronavirus.
Credit: Amy Drexelius

Device could preconcentrate samples from COVID-19 patients in asymptomatic stages of the disease, providing early detection capability.

Diagnostic devices that are used at home or in doctors’ offices are often not sensitive enough to detect small amounts of a virus that might be present in samples from asymptomatic patients, which can occur in early stage COVID-19. In Biomicrofluidics, by AIP Publishing, scientists report a membrane-based invention that can concentrate the virus content of a sample of urine or saliva, allowing it to be detected.

To increase sample concentration, previous groups have used gel particles, coupled to a chemical dye, to trap and detect a virus, but this approach is restricted to specific viruses that can bind to the dye. In addition, the testing time can be more than 30 minutes and requires expensive equipment.

Other approaches have been tried, but all lack the ability to diagnose different viruses or other biosubstances of interest, such as human chorionic gonadotropin, a hormone present in the urine during pregnancy.

Researchers at the University of Cincinnati and Wright-Patterson Air Force Base tried two different devices, both based on similar membrane-filter systems.

The first device was a fully integrated concentration unit coupled with a component that could detect the virus in question. A vacuum was used to pull water through the membrane, leaving behind the virus in a more concentrated solution, and the sample was analyzed in the same device.

“The amount of time needed to complete the concentration process was very slow,” said author Amy Drexelius. “On average, each device took about 30 minutes to complete the concentration process. We, therefore, concluded that the vacuum driven auto-staging device is not practically useful and turned to an alternate device utilizing a much higher positive pressure.”

The second device was considered because the investigators realized that by applying high pressure, instead of high vacuum, they could increase the pressure differential between the sample and the surroundings. A nitrogen gas tank and regulator were attached to their second device, allowing the application of up to 100 pounds per square inch of pressure.

The group investigated real biofluids, saliva and urine, spiked with samples of protein from influenza A virus. Other samples contained HCG.

“The test results were extremely consistent with the second device, showing a concentration result of 33 times that of the original sample,” said Drexelius. “Preconcentration of a 1-milliliter sample could be achieved in five minutes or even faster with higher applied pressures.”

The novel coronavirus that causes COVID-19 was not tested, but the method should work for it, since the technology could successfully detect influenza A. Both are respiratory viruses likely to be present in saliva. The technique is, in addition, promising for pregnancy testing, where early results are also highly desirable.

###

The article, “Analysis of pressure-driven membrane preconcentration for point-of-care assays,” is authored by Amy Drexelius, Anna Hoellrich, Andrew Jajack, Eliot Gomez, Michael Brothers, Saber Hussain, Steve S. Kim, and Jason Heikenfeld. The article will appear in Biomicrofluidics on Sept. 1, 2020 (DOI: 10.1063/5.0013987). After that date, it can be accessed at https://aip.scitation.org/doi/10.1063/5.0013987.

ABOUT THE JOURNAL

Biomicrofluidics rapidly disseminates research in fundamental physicochemical mechanisms associated with microfluidic and nanofluidic phenomena. The journal also publishes research in unique microfluidic and nanofluidic techniques for diagnostic, medical, biological, pharmaceutical, environmental, and chemical applications. See https://aip.scitation.org/journal/bmf.

Media Contact

Larry Frum
media@aip.org
301-209-3090

http://www.aip.org 

Related Journal Article

http://dx.doi.org/10.1063/5.0013987

Media Contact

Larry Frum
American Institute of Physics

All latest news from the category: Health and Medicine

This subject area encompasses research and studies in the field of human medicine.

Among the wide-ranging list of topics covered here are anesthesiology, anatomy, surgery, human genetics, hygiene and environmental medicine, internal medicine, neurology, pharmacology, physiology, urology and dental medicine.

Back to home

Comments (0)

Write a comment

Newest articles

Superradiant atoms could push the boundaries of how precisely time can be measured

Superradiant atoms can help us measure time more precisely than ever. In a new study, researchers from the University of Copenhagen present a new method for measuring the time interval,…

Ion thermoelectric conversion devices for near room temperature

The electrode sheet of the thermoelectric device consists of ionic hydrogel, which is sandwiched between the electrodes to form, and the Prussian blue on the electrode undergoes a redox reaction…

Zap Energy achieves 37-million-degree temperatures in a compact device

New publication reports record electron temperatures for a small-scale, sheared-flow-stabilized Z-pinch fusion device. In the nine decades since humans first produced fusion reactions, only a few fusion technologies have demonstrated…

Partners & Sponsors