Body-Surface-Potential-Maps by utilizing a standard ECG device

<strong>Technology</strong><br>

Receiving a standard 12-lead electro-cardiogram (ECG) is a well established method to get information of the heart's electrical activity recorded from electrodes on the body surface. In comparison to standard ECG, Body-Surface-Potential-Mapping (BSPM) is an advanced method providing more extensive and precise diagnostic data. The reason for an improved detection and separation of pathophysiological heart function by BSPM is due to the much larger number of sampling positions of the electrodes attached to the thorax. Hence, spatially and temporally important features may be captured by BSPM but not by the 12-lead-ECG. So far, high cost and complexity have presented widespread use of BSPM in clinical settings.<br> Our new method requires only a standard 12-lead ECG device with digital data output providing almost identical results as BSPM. The only real differ-ence is that not all channels are being read out simultaneously, i.e. the map-ping is reconstructed from sequentially obtained ECG-Signals. A specific digital signal processing has been developed to synchronize sequentially recorded ECG signals. The resulting data is thus competitive to the “true” parallel BSPM. </p> <b>Benefits:</b> <ul> <li>Additional benefit for users of 12-lead-EVG devices</li> <li>Simple and cost-effective method to get additional clinically relevant data</li> <li>The algorithms may easily be added to the software of commercial digital ECG devices<span style=”font-size: 10pt; font-family: “TheSansOffice”,”sans-serif”;” lang=”EN-GB”> </span></li> </ul> <p><strong>IP Rights</strong><br> German Patent DE 10 336 809 B4; European Patent Application EP 1653851 A1</p> <p><strong>Origin</strong><br> Charité, Campus Benjamin Franklin, Berlin, Germany; Physikalisch-Technische Bundesanstalt (PTB), Berlin, Germany</p> <b>Find the technology offer and contact details here: <a href=”http://www.ipal.de/technologieangebote/03017″ target=”_blank”>http://www.ipal.de/technologieangebote/03017</a></b>

Further Information: PDF

ipal GmbH
Phone: +49 (0)30/2125-4820

Contact
Dr. Dirk Dantz

Media Contact

info@technologieallianz.de TechnologieAllianz e.V.

All latest news from the category: Technology Offerings

Back to home

Comments (0)

Write a comment

Newest articles

Superradiant atoms could push the boundaries of how precisely time can be measured

Superradiant atoms can help us measure time more precisely than ever. In a new study, researchers from the University of Copenhagen present a new method for measuring the time interval,…

Ion thermoelectric conversion devices for near room temperature

The electrode sheet of the thermoelectric device consists of ionic hydrogel, which is sandwiched between the electrodes to form, and the Prussian blue on the electrode undergoes a redox reaction…

Zap Energy achieves 37-million-degree temperatures in a compact device

New publication reports record electron temperatures for a small-scale, sheared-flow-stabilized Z-pinch fusion device. In the nine decades since humans first produced fusion reactions, only a few fusion technologies have demonstrated…

Partners & Sponsors