Forum for Science, Industry and Business

Sponsored by:     3M 
Search our Site:

 

New 'real-world' reassuring data from the SCAAR registry

09.01.2012
New generation drug-eluting stents associated with lower rates of mortality and restenosis than bare metal stents

A registry -which includes every patient in Sweden having percutaneous coronary intervention (PCI) for the treatment of acute and stable coronary artery disease- has found that PCI implantations using a new generation of drug-eluting stents is associated with lower rates of relapse (restenosis), stent thrombosis and subsequent mortality than older generation drug-eluting stents and bare-metal stents.(1)

The findings, from the Swedish Coronary Angiography and Angioplasty Registry (SCAAR), reported in the European Heart Journal, represent the outcome of treatment in a large "real-world population", and were derived from an analysis of 94,384 consecutive stent implantations performed in Sweden between November 2006 and October 2010.

An earlier study from the SCAAR registry, evaluating stent implantations between 2003 and 2004, had dramatically shown that those treated with drug-eluting stents (DES) had a higher rate of later mortality than those receiving bare-metal stents (BMS).(2) The results caused uproar, and prompted an immediate decline in the use of DES and an urgent review of their safety. However, follow-up of the same patient cohort two years later (with data extended to 2006) found no increased risk of death between the two groups.(3) The difference in outcome was largely explained by improvements in cardiology practice (including the application of dual antiplatelet therapy after PCI) and the introduction of improved devices.

Conclusions in this latest report, from what is the world's largest PCI registry with the longest follow-up of data, now confirm that mortality rates associated with both the new and old generations of DES were significantly lower than found with BMS. The risk of death was 28% lower with the old generation DES and 45% lower with the new generation; moreover, the new generation DES were associated with a 23% lower mortality rate at two years than the old generation DES.

The authors note that this is the first time any mortality reduction has been shown between DES and BMS, either in randomised trials or in reports from the SCAAR registry itself.

The study also found that the new generation of DES was associated with a 38% lower risk of restenosis and a 43% lower risk of stent thrombosis within two years of implantation than BMS. Late stent thrombosis has been a recurring safety concern with the original DES; the authors suggest that the new generation DES, with "thin, more biocompatible polymers" and greater flexibility, may have contributed to lowering this thrombotic risk.

Speaking on behalf of the SCAAR investigators, cardiologist Dr Stefan James from Uppsala University Hospital in Sweden described the latest findings as "intriguing" - not just because of the lower rates of restenosis with the latest generation of DES, which were expected, but also of stent thrombosis and mortality. "The low rates of restenosis and stent thrombosis correspond with the results of several recent randomised trials," said Dr James, "and this may well translate into mortality reduction in a sufficiently large study population."

However, he warned that all observational data should be interpreted with caution. "Despite the use of appropriate statistical methods," he said, "there may be residual confounding because of differences in concealed baseline variables." Nevertheless, this SCAAR analysis included only patients who where treated after 2006, to ensure that both the older and newer generation DES were used. "Since 2006 no major changes in recommendations for antithrombotic strategies or duration of dual antiplatelet therapy have occurred in Sweden," said Dr James, "so it seems likely that our more favourable outcomes are true findings."

The investigators say their results now add further weight to the strong recommendation for the use of DES as a default strategy in patients expected to tolerate extended dual antiplatelet therapy, in the treatment of coronary artery disease. "But our results also reinforce the need for randomised trials to evaluate the optimal strategy and duration of antithrombotic therapy following PCI in various indications," said Dr James.

Notes for editors

1. Sarno G, Lagerqvist B, Frober O, et al. Lower risk of stent thrombosis and restenosis with unrestricted use of 'new-generation' drug-eluting stents: a report from the nationwide Swedish Coronary Angiography and Angioplasty Registry (SCAAR). Eur Heart J 2012; doi:10.1093/eurheartj/ehr479

2. Lagerqvist B, James SK, Stenestrand U, et al. Long-term outcomes with drug-eluting stents versus bare-metal stents in Sweden. N Engl J Med 2007; 356: 1009-1019.

3. James SK, Stenestrand U, Lindback J, et al. Long-term safety and efficacy of drug-eluting versus bare-metal stents in Sweden. N Engl J Med 2009; 360: 1933-1945.

* Drug-eluting stents are metallic mesh tubes which keep open narrowed coronary arteries while slowly releasing a medication to prevent the build-up of scar tissue inside the stent.

* The European Heart Journal is a journal of the European Society of Cardiology.

* More information on this press release, interview contacts and a PDF of the paper is available from the ESC's press office: press@escardio.org

ESC Press Office | EurekAlert!
Further information:
http://www.escardio.org

More articles from Health and Medicine:

nachricht A promising target for kidney fibrosis
21.04.2017 | Brigham and Women's Hospital

nachricht Stem cell transplants: activating signal paths may protect from graft-versus-host disease
20.04.2017 | Technische Universität München

All articles from Health and Medicine >>>

The most recent press releases about innovation >>>

Die letzten 5 Focus-News des innovations-reports im Überblick:

Im Focus: Deep inside Galaxy M87

The nearby, giant radio galaxy M87 hosts a supermassive black hole (BH) and is well-known for its bright jet dominating the spectrum over ten orders of magnitude in frequency. Due to its proximity, jet prominence, and the large black hole mass, M87 is the best laboratory for investigating the formation, acceleration, and collimation of relativistic jets. A research team led by Silke Britzen from the Max Planck Institute for Radio Astronomy in Bonn, Germany, has found strong indication for turbulent processes connecting the accretion disk and the jet of that galaxy providing insights into the longstanding problem of the origin of astrophysical jets.

Supermassive black holes form some of the most enigmatic phenomena in astrophysics. Their enormous energy output is supposed to be generated by the...

Im Focus: A Quantum Low Pass for Photons

Physicists in Garching observe novel quantum effect that limits the number of emitted photons.

The probability to find a certain number of photons inside a laser pulse usually corresponds to a classical distribution of independent events, the so-called...

Im Focus: Microprocessors based on a layer of just three atoms

Microprocessors based on atomically thin materials hold the promise of the evolution of traditional processors as well as new applications in the field of flexible electronics. Now, a TU Wien research team led by Thomas Müller has made a breakthrough in this field as part of an ongoing research project.

Two-dimensional materials, or 2D materials for short, are extremely versatile, although – or often more precisely because – they are made up of just one or a...

Im Focus: Quantum-physical Model System

Computer-assisted methods aid Heidelberg physicists in reproducing experiment with ultracold atoms

Two researchers at Heidelberg University have developed a model system that enables a better understanding of the processes in a quantum-physical experiment...

Im Focus: Glacier bacteria’s contribution to carbon cycling

Glaciers might seem rather inhospitable environments. However, they are home to a diverse and vibrant microbial community. It’s becoming increasingly clear that they play a bigger role in the carbon cycle than previously thought.

A new study, now published in the journal Nature Geoscience, shows how microbial communities in melting glaciers contribute to the Earth’s carbon cycle, a...

All Focus news of the innovation-report >>>

Anzeige

Anzeige

Event News

Expert meeting “Health Business Connect” will connect international medical technology companies

20.04.2017 | Event News

Wenn der Computer das Gehirn austrickst

18.04.2017 | Event News

7th International Conference on Crystalline Silicon Photovoltaics in Freiburg on April 3-5, 2017

03.04.2017 | Event News

 
Latest News

New quantum liquid crystals may play role in future of computers

21.04.2017 | Physics and Astronomy

A promising target for kidney fibrosis

21.04.2017 | Health and Medicine

Light rays from a supernova bent by the curvature of space-time around a galaxy

21.04.2017 | Physics and Astronomy

VideoLinks
B2B-VideoLinks
More VideoLinks >>>