Two-dimensional (2-D) x-ray mammography, the current primary screening method for early detection of breast cancer in women, is a valuable tool but has some limitations. Surrounding normal tissue can mask lesions, and 2-D views do not provide direct information about the volumetric appearance—meaning the three-dimensional physical shape—of a detected lesion.
A novel technique called stereoscopic digital mammography (SDM) addresses these limitations by mimicking the way that human eyes work together to form a 3-D image. The technique uses digital mammography equipment that's been modified to allow the X-ray tube to move separately from the cassette. The resulting images are viewed on two monitors mounted one above the other.
"Our eyes see the world from two slightly different perspectives," said Carl J. D'Orsi, M.D., from the Department of Radiology and Imaging Sciences at Emory University School of Medicine and the Winship Cancer Institute at Emory University, both in Atlanta. "In this technique, the X-ray tube functions as the eyeball, with two different images providing slightly different views of the internal structure of the breast."
By using a unique workstation and polarizing lenses, SDM has the ability to identify lesions at different depths within the breast volume, potentially reducing both false positive findings and recalls while enabling more accurate diagnosis.
Dr. D'Orsi and colleagues recently compared SDM to 2-D digital mammography in 779 patients at elevated risk of developing breast cancer because of personal or family history. Patients received both exams in a single visit, and two experienced radiologists independently interpreted the final total of 1,298 exams. Imaging findings were correlated with results of one-year follow up or biopsy.
SDM significantly improved the accuracy of cancer detection. The specificity of 91.2 percent was better than the 87.8 percent rate for 2-D digital mammography; and the accuracy of 90.9 percent, compared with 87.4 percent for 2-D digital mammography, was also a statistically significant improvement.
"We found that the stereoscopic technique could significantly decrease the need for calling women back for additional exams," Dr. D'Orsi said.
Dr. D'Orsi and colleagues are expanding their research to study
SDM with a lower radiation dose in the general screening population. The radiation dose used in the study was approximately double the standard dose for mammography.
"In this study, we used a high-risk population to get an adequate number of cancers, and we acquired each of the images comprising the stereo pairs with a full standard X-ray dose," he said. "Now that we know the technique is worthwhile, we're repeating the study in the general population with a dose comparable to routine screening mammography."
"Stereoscopic Digital Mammography: Improved Specificity and Reduced Rate of Recall in a Prospective Clinical Trial." Collaborating with Dr. D'Orsi were David J. Getty, Ph.D., Ronald M. Pickett, Ph.D., Ioannis Sechopoulos, Ph.D., Mary S. Newell, M.D., Kathleen R. Gundry, M.D., Sandra R. Bates, M.D., Robert M. Nishikawa, Ph.D., Edward A. Sickles, M.D., Andrew Karellas, Ph.D., and Ellen M. D'Orsi, R.T. (R)(M).
Radiology is edited by Herbert Y. Kressel, M.D., Harvard Medical School, Boston, Mass., and owned and published by the Radiological Society of North America, Inc. (http://radiology.rsna.org/)
RSNA is an association of more than 50,000 radiologists, radiation oncologists, medical physicists and related scientists, promoting excellence in patient care and health care delivery through education, research and technologic innovation.
The Society is based in Oak Brook, Ill. (RSNA.org)
For patient-friendly information on breast imaging, visit RadiologyInfo.org.
Linda Brooks | Source: EurekAlert!
Further information: www.rsna.org
Further Reports about: 2-D pictures > 3-D image > breast cancer > digital mammography > human eye > radiation dose > Radiological Society > radiology > Stereoscopic > X-ray microscopy > X-ray tube
More articles from Medical Engineering:
Robotic transplant an option for obese kidney patients
16.05.2013 | University of Illinois at Chicago
Intermountain Medical Center reseachers develop new 3-D technology to treat atrial fibrillation
13.05.2013 | Intermountain Medical Center
University of Würzburg physicists have succeeded in creating a new type of laser.
Its operation principle is completely different from conventional devices, which opens up the possibility of a significantly reduced energy input requirement. The researchers report their work in the current issue of Nature.
It also emits light the waves of which are in phase with one another: the polariton laser, developed ...
Innsbruck physicists led by Rainer Blatt and Peter Zoller experimentally gained a deep insight into the nature of quantum mechanical phase transitions.
They are the first scientists that simulated the competition between two rival dynamical processes at a novel type of transition between two quantum mechanical orders. They have published the results of their work in the journal Nature Physics.
“When water boils, its molecules are released as vapor. We call this ...
Researchers have shown that, by using global positioning systems (GPS) to measure ground deformation caused by a large underwater earthquake, they can provide accurate warning of the resulting tsunami in just a few minutes after the earthquake onset.
For the devastating Japan 2011 event, the team reveals that the analysis of the GPS data and issue of a detailed tsunami alert would have taken no more than three minutes. The results are published on 17 May in Natural Hazards and Earth System Sciences, an open access journal of ...
A new study of glaciers worldwide using observations from two NASA satellites has helped resolve differences in estimates of how fast glaciers are disappearing and contributing to sea level rise.
The new research found glaciers outside of the Greenland and Antarctic ice sheets, repositories of 1 percent of all land ice, lost an average of 571 trillion pounds (259 trillion kilograms) of mass every year during the six-year study period, making the oceans rise 0.03 inches (0.7 mm) per year. ...
About 99% of the world’s land ice is stored in the huge ice sheets of Antarctica and Greenland, while only 1% is contained in glaciers.
However, the meltwater of glaciers contributed almost as much to the rise in sea level in the period 2003 to 2009 as the two ice sheets: about one third. This is one of the results of an international study with the involvement of geographers from the University of Zurich.
How ...
Graphene Study Confirms 40-Year-Old Physics Prediction
21.05.2013 | Studies and Analyses
In Early Earth, Iron Helped RNA Catalyze Electron Transfer
21.05.2013 | Life Sciences
New era of fisheries policy needed to secure nutrition for millions
21.05.2013 | Studies and Analyses
ITS European Congress: Traffic Warning and Information Platform
17.05.2013 | Event News
European Research Infrastructures help to solve air quality issues
15.05.2013 | Event News
The Problem of the European Unemployment
08.05.2013 | Event News