Until now doctors have used expensive and complicated electronic devices which sent the measured data to the outside world as radio signals. On the other hand, according to Felix Gattiker of Empa’s Electronics, Metrology and Reliability Laboratory, an electronics-free sensor offers many advantages – not least of the financial kind. In the new Empa sensor the data is read out by means of an ultrasonic scanner.
The solution is in the form of a small, hollow spiral which sits on the implant together with a fluid reservoir. When the implant is subject to compression or tension the level of fluid in the spiral changes. This level is measured with the help of an ultrasonic device, and the resulting data allows the mechanical loading on the implant to be calculated.
The ultrasonic image is, however, too indistinct to allow the fluid level to be determined visually, so the Empa researchers decided to analyze the ultrasonic signal in more detail. They quickly found a dependence between the ultrasonic echo generated over the complete spiral and the actual fill level – the weaker the ultrasonic echo measured, the higher the level, and therefore the greater the force acting on the sensor.
Further research is already in the pipeline
The sensor produces reliable measurement data, as numerous experiments with artificial tissues – mixtures of gelling agent, glass ballotini and graphite powder, which depending on the mixing ratios allow different types of tissue to be simulated – have demonstrated. Not only that, it is also economic to manufacture, being very much cheaper than the existing electronic versions. The next step is to test the accuracy of the new method using various animal tissues, since each material has its own acoustic signature because it reflects and absorbs ultrasonic energy differently.
In addition, the Empa scientists are investigating the idea of making the sensor out of biodegradable materials, in which case the device would simply dissolve away in the patient’s body after completing its task. The surgeon need not therefore sharpen his scalpel a second time, there being no need to remove the sensor when the fracture has healed! And finally, there is the outstanding matter of finding an industrial partner to manufacture the sensors and integrate them into the implants.
Remigius Nideroest | Source: alphagalileo
Further information: www.empa.ch
www.empa.ch/plugin/template/empa/1142/75011/---/l=2/changeLang=true/lartid=75011/orga=/type=/theme=/bestellbar=/new_abt=/uacc=
Further Reports about: biodegradable materials > electronics-free sensor > Empa > fracture > implants > Monitoring > Monitoring broken bones > Sensor > ultrasonic image > wireless bone monitor
More articles from Medical Engineering:
EKG can show false positive readings for diagnosing heart condition
17.11.2009 | Henry Ford Health System
Barrow study identifies new way to biopsy brain tumors in real time
13.11.2009 | St. Joseph's Hospital and Medical Center
Scientists Unravel Evolution of Highly Toxic Box Jellyfish
20.11.2009 | Life Sciences
When good companies do bad things: Examining illegal corporate behavior
20.11.2009 | Business and Finance
UCR plant scientist's research spawns new discoveries showing how crops survive drought
20.11.2009 | Agricultural and Forestry Science
Multidisciplinary meeting on Urological Cancers aims to benefit cancer patients
20.11.2009 | Event News
'Golden Age' for clinical psychology in Northern Ireland
20.11.2009 | Event News
New Perspectives in Marine Anti-Fouling Research
11.11.2009 | Event News