Ultrasound-guided surgery is best way to remove breast tumours

23.03.2012
Technique should become the new standard of care

The use of ultrasound-guided surgery to remove tumours from women who have palpable breast cancer is much more successful than standard surgery in excising all the cancerous tissue while sparing as much healthy tissue as possible, according to the results of a randomised controlled trial.

As a consequence, researchers told the eighth European Breast Cancer Conference (EBCC-8) today (Friday) they expect their findings will change surgical practice and ultrasound-guided surgery (USS) should become the norm for excising palpable tumours i.e. those that can be felt and, at present, are excised "blindly", without visual aid from tools to help locate the precise position of the tumour during surgery.

When surgeons opt for breast conserving surgery and remove only the tumour rather than the whole breast, they need to include a margin of cancer-free tissue around the tumour during the surgery. This is so that they can be fairly sure that they have removed all the cancerous tissue in order to reduce the chance of local recurrence to a minimum when combined with standard radiotherapy. The margin of "healthy" tissue is analysed to check that it is free of cancer cells, and if it is not, then further surgery, or an additional radiotherapy boost may be required.

Dr Nicole Krekel, a PhD student in the department of surgical oncology and resident doctor in plastic and reconstructive surgery at VU University Medical Center in Amsterdam, The Netherlands, told the meeting: "Breast-conserving surgery for palpable breast cancer is generally performed with guidance from surgeon's palpation only, without help from intra-operative tumour localisation techniques. The standard method of surgery for non-palpable breast cancer involves a wire to identify the area of cancerous tissue that the surgeon needs to remove – a technique known as wire localisation. Unfortunately, both methods of excision are associated with a high rate of margins that contain cancer cells, as well as the excision of excessively large volumes of tissue. Despite studies showing the benefits of USS over wire localisation for non-palpable breast cancer, remarkably USS has not been widely integrated into daily surgical practice. In contrast to non-palpable tumours, there has been little research into the use of USS for palpable breast cancer."

Dr Krekel and her colleagues randomised 124 patients with palpable early stage breast cancer to either USS or standard palpation-guided surgery (PGS). They found that among the 61 women in the USS group only 3.3% of the margins contained cancerous cells compared with 16.4% among the 63 women in the PGS group. As a result, USS resulted in a significant reduction in re-excisions, mastectomies and extra radiotherapy. The amount of healthy tissue removed in the USS group was smaller than in the PGS group (40 cubic centimetres versus 58 cc respectively).

By measuring the volume of the tissue excised during surgery and the actual tumour diameters, the researchers calculated the amount of excess healthy tissue that had been removed, which gave them the "calculated resection ratio" (CRR). A CRR of 1.0 would indicate the ideal amount of tissue had been removed, while a CRR of 2.0 would indicate that double the amount necessary had been removed. They found that the CRR in the USS group was 1.0 (ideal), while in the PGS group it was 1.9.

"Our results show that USS can prevent the unacceptably high rate of margins containing cancer cells in palpable breast cancer excision, thus avoiding subsequent surgery or radiotherapy. In addition, USS largely reduces the amount of unnecessary healthy breast tissue resection, thereby contributing to the improvement of cosmetic results," said Dr Krekel.

"The trial was only completed in February this year and the results are striking. By using USS, 96.7% of all tumours were excised with adequate, tumour-free margins, compared with only 83.4% in the PGS group, yet the volume of tissue excised was significantly smaller in the USS group.

"The clinical implications of our study are tremendous and we believe they should be included in international guidelines. Given the overwhelming advantages of ultrasound-guided surgery, 'blind', palpation-guided excisions should be completely replaced, with ultrasound-guided surgery becoming the standard of care for both palpable and non-palpable breast cancer surgery. The surgeon performing adequate ultrasound will clearly provide better surgical practice. It is therefore highly recommended for surgeons to learn the skills needed to perform USS."

Dr Krekel said the reason why USS was superior to PGS was because it enabled surgeons to see all round the tumour while they were performing the operation. "Intra-operative US enables the surgeon to optimally position the incision on the breast, and to operate under direct vision. This provides the surgeon with more precision in localising tumours and determining the size of the lesions than palpation alone, and allows intra-operative orientation, and assessment of surgical margins. It allows complete tumour removal, while continuously monitoring the maintenance of adequate, small resection margins without unnecessarily sacrificing healthy breast tissue. After excision, the completeness of tumour excision can be checked once again with US. The technique is non-invasive, simple, safe and effective, and can be easily learned, " she explained.

Professor David Cameron, from the University of Edinburgh (Edinburgh, UK), and chair of EBCC-8 said: "This study offers the promise of more successful breast conserving surgery for women with early breast cancer. If the pathologist reports that there is still cancer present at the margin of an excision, usually more surgery is needed: importantly, this study offers a way to reduce the chance of this. However, it is a report from only one hospital, and these findings need confirmation from other teams of surgeons before they should become standard practice."

Abstract no: 1 LBA, Friday 15.00 hrs, Keynote symposium, Hall D

Emma Mason | EurekAlert!
Further information:
http://www.ecco-org.eu

More articles from Medical Engineering:

nachricht Novel PET tracer identifies most bacterial infections
06.10.2017 | Society of Nuclear Medicine and Molecular Imaging

nachricht Teleoperating robots with virtual reality
05.10.2017 | Massachusetts Institute of Technology, CSAIL

All articles from Medical Engineering >>>

The most recent press releases about innovation >>>

Die letzten 5 Focus-News des innovations-reports im Überblick:

Im Focus: Neutron star merger directly observed for the first time

University of Maryland researchers contribute to historic detection of gravitational waves and light created by event

On August 17, 2017, at 12:41:04 UTC, scientists made the first direct observation of a merger between two neutron stars--the dense, collapsed cores that remain...

Im Focus: Breaking: the first light from two neutron stars merging

Seven new papers describe the first-ever detection of light from a gravitational wave source. The event, caused by two neutron stars colliding and merging together, was dubbed GW170817 because it sent ripples through space-time that reached Earth on 2017 August 17. Around the world, hundreds of excited astronomers mobilized quickly and were able to observe the event using numerous telescopes, providing a wealth of new data.

Previous detections of gravitational waves have all involved the merger of two black holes, a feat that won the 2017 Nobel Prize in Physics earlier this month....

Im Focus: Smart sensors for efficient processes

Material defects in end products can quickly result in failures in many areas of industry, and have a massive impact on the safe use of their products. This is why, in the field of quality assurance, intelligent, nondestructive sensor systems play a key role. They allow testing components and parts in a rapid and cost-efficient manner without destroying the actual product or changing its surface. Experts from the Fraunhofer IZFP in Saarbrücken will be presenting two exhibits at the Blechexpo in Stuttgart from 7–10 November 2017 that allow fast, reliable, and automated characterization of materials and detection of defects (Hall 5, Booth 5306).

When quality testing uses time-consuming destructive test methods, it can result in enormous costs due to damaging or destroying the products. And given that...

Im Focus: Cold molecules on collision course

Using a new cooling technique MPQ scientists succeed at observing collisions in a dense beam of cold and slow dipolar molecules.

How do chemical reactions proceed at extremely low temperatures? The answer requires the investigation of molecular samples that are cold, dense, and slow at...

Im Focus: Shrinking the proton again!

Scientists from the Max Planck Institute of Quantum Optics, using high precision laser spectroscopy of atomic hydrogen, confirm the surprisingly small value of the proton radius determined from muonic hydrogen.

It was one of the breakthroughs of the year 2010: Laser spectroscopy of muonic hydrogen resulted in a value for the proton charge radius that was significantly...

All Focus news of the innovation-report >>>

Anzeige

Anzeige

Event News

ASEAN Member States discuss the future role of renewable energy

17.10.2017 | Event News

World Health Summit 2017: International experts set the course for the future of Global Health

10.10.2017 | Event News

Climate Engineering Conference 2017 Opens in Berlin

10.10.2017 | Event News

 
Latest News

Terahertz spectroscopy goes nano

20.10.2017 | Information Technology

Strange but true: Turning a material upside down can sometimes make it softer

20.10.2017 | Materials Sciences

NRL clarifies valley polarization for electronic and optoelectronic technologies

20.10.2017 | Interdisciplinary Research

VideoLinks
B2B-VideoLinks
More VideoLinks >>>