Digital mammography superior to film mammography in some cases

“We looked at a cross-section of characteristics,” said DMIST principal investigator, Etta D. Pisano, M.D., Kenan professor of radiology and biomedical engineering at the University of North Carolina School of Medicine in Chapel Hill. “This paper confirms that if you are under 50, pre- or perimenopausal, and have dense breasts, you should definitely be screened with digital rather than film.”

DMIST enrolled 49,528 women at 33 centers in the U.S. and Canada. The women underwent both digital and film mammography. Breast cancer status was determined for 42,760 women.

“The original DMIST results showed that digital was statistically similar to film in the overall screening population but performed better than film in pre- and perimenopausal women under 50,” Dr. Pisano said.

For this paper, the researchers sought to retrospectively compare the accuracy of digital mammography versus film mammography in subgroups defined by combinations of age, menopausal status and breast density, using either biopsy results or follow-up information.

They compared results in 10 different subgroups of women: pre- and perimenopausal women under age 50 with fatty breasts, pre- and perimenopausal women under age 50 with dense breasts, postmenopausal women under 50 with fatty breasts, postmenopausal women under 50 with dense breasts, pre- and perimenopausal women between the ages of 50 and 64 with fatty breasts, pre- and perimenopausal women age 50 to 64 with dense breasts, postmenopausal women age 50 to 64 with fatty breasts, postmenopausal women age 50 to 64 with dense breasts, women over age 65 with fatty breasts and women over 65 with dense breasts.

The results confirmed the trial’s original findings in favor of improved diagnostic accuracy of digital mammography over film for pre- and perimenopausal women under 50 years old with dense breasts. The findings also showed a trend toward improved diagnostic accuracy of film over digital mammography for women over 65 with fatty breasts. However, this finding was not statistically significant, and further investigation is needed to determine the reason that film performed slightly better in this subgroup. For other groups evaluated, there was no significant difference.

Media Contact

Linda Brooks EurekAlert!

More Information:

http://www.rsna.org

All latest news from the category: Medical Engineering

The development of medical equipment, products and technical procedures is characterized by high research and development costs in a variety of fields related to the study of human medicine.

innovations-report provides informative and stimulating reports and articles on topics ranging from imaging processes, cell and tissue techniques, optical techniques, implants, orthopedic aids, clinical and medical office equipment, dialysis systems and x-ray/radiation monitoring devices to endoscopy, ultrasound, surgical techniques, and dental materials.

Back to home

Comments (0)

Write a comment

Newest articles

Properties of new materials for microchips

… can now be measured well. Reseachers of Delft University of Technology demonstrated measuring performance properties of ultrathin silicon membranes. Making ever smaller and more powerful chips requires new ultrathin…

Floating solar’s potential

… to support sustainable development by addressing climate, water, and energy goals holistically. A new study published this week in Nature Energy raises the potential for floating solar photovoltaics (FPV)…

Skyrmions move at record speeds

… a step towards the computing of the future. An international research team led by scientists from the CNRS1 has discovered that the magnetic nanobubbles2 known as skyrmions can be…

Partners & Sponsors