Innovative imaging system may boost speed and accuracy in treatment of heart rhythm disorder

University of Maryland researchers link 3-D CT scans to standard ablation techniques

Researchers at the University of Maryland School of Medicine in Baltimore have developed a novel 3-D imaging approach that may improve the accuracy of treatment for ventricular tachycardia, a potentially life-threatening heart rhythm disorder that causes the heart to beat too fast.

The new approach couples CT (computed tomography) images with conventional ablation techniques to eliminate erratic electrical circuits in the heart that produce arrhythmias. The results of a feasibility study have been published online in Circulation: Arrhythmia and Electrophysiology, a journal of the American Heart Association.

Electrical signals control how frequently the heart beats and how the heart muscle contracts to move blood through the body. Following a heart attack, irregularly shaped sections of dead scar tissue may form in the heart and block the electrical flow or cause a short circuit. The researchers say a growing number of people who have survived severe heart attacks go on to face a weak, erratic heartbeat, and that has prompted the search for more effective ways to treat these electrical disturbances.

Current ablation procedures, which use high-energy radio waves to treat certain types of serious arrhythmias, have only 50-60 percent long-term success. The research team theorized that with the aid of sophisticated 3-D CT imaging, treatment may be more precise and take less time.

According to the study’s senior author, Timm-Michael L. Dickfeld, M.D., Ph.D., associate professor of medicine at the University of Maryland School of Medicine, “We can use 3-D CT imaging to guide us more rapidly to areas of the heart that may cause the electrical abnormalities responsible for ventricular tachycardia, and move away from parts of the heart that do not contribute to the abnormalities.” Dr. Dickfeld is a cardiologist at the University of Maryland Medical Center and chief of electrophysiology at the Baltimore VA Medical Center.

A CT scanner, which takes multiple X-ray images in a matter of seconds as it rapidly spirals around the body, yields three significant types of information about the heart; abnormal cardiac anatomy, blood flow and heart muscle contraction. After two years of testing and customizing software, the research team has succeeded in combining all of these factors into a three-dimensional imaging format that can work accurately with existing equipment in an electrophysiology laboratory, where ablation procedures are performed.

This project builds on the team’s earlier work that studied how well a combination of PET (positron emission tomography) and CT technology would provide advanced imaging. Study co-author Jean Jeudy, M.D., a radiologist at the University of Maryland Medical Center and assistant professor of diagnostic radiology and nuclear medicine at the University of Maryland School of Medicine, says information from imaging technologies such as CT and PET has been used independently, up till now. “Each modality has advantages in imaging, but our idea is to pool their strengths to create a synergism that results in the best and safest therapies for patients.”

Study design and results

Eleven men with ventricular tachycardia were evaluated in the study. Each had had a heart attack and required an implantable cardioverter-defibrillator to correct problems with their heartbeat. The participants were scanned for a total of 10-15 seconds with a 64-slice CT system. The scan data was reconstructed into 3-D images and compared to the clinical electrical mapping system routinely used to determine where to apply ablations.

The study’s principal investigator, Jing Tian, B.M., Ph.D., says CT imaging was used only as a supplement to find the location of scars. To assess the potential value of this novel technology, the research team compared data from the 3-D imaging with the clinical data after ablations were performed on the patients in the study. “We found that the 3-D scar reconstruction from CT imaging predicted areas of abnormal electrical activity in 81.7 percent of heart segments analyzed. The imaging also correctly displayed the location and extent of cardiac scar tissue, determined by voltage mapping – the gold standard for scar definition in current clinical practice,” says Dr. Tian, a research associate at the University of Maryland School of Medicine. “Curative ablations were located within tissue that CT had identified as abnormal in 82 percent of the cases.”

In order to clarify the utility of the 3-D imaging technology, Dr. Tian says there would have to be a randomized, controlled trial to quantify how much time can be saved, how much less radiation it requires, and the impact on patient care. “Such a trial would be the next step,” she adds.

Ventricular tachycardia

A healthy heart beats about 60 to 100 beats per minute, and may beat faster with exercise or during stress or fever. In ventricular tachycardia, the heart routinely beats more than 100 times a minute. This rapid heartbeat can lead to dizziness or lightheadedness, fainting and shortness of breath, and may set the stage for sudden cardiac arrest.

Some patients respond well to medications that restore normal heartbeat, while others require a shock from an implantable cardioverter-defibrillator (ICD) to restore normal rhythm. The medications have side effects and the electrical disturbances in some people are so frequent that the ICD must fire multiple corrective shocks each day to prevent sudden cardiac arrest. The shocks are painful, causing many patients to fear their next shock. The goal of ablation is to burn a barrier around the scars to end the electrical disturbance and restore normal heart rhythm. For some patients, the procedure reduces the number of corrective shocks and eliminates the need for medication.

“Advances in cardiac care and the availability of defibrillators have helped many people with weakened hearts live longer,” says E. Albert Reece, M.D., Ph.D., M.B.A., vice president for medical affairs at the University of Maryland and dean of the University of Maryland School of Medicine. “Nevertheless, the devices create their own set of problems, especially for people who have received multiple shocks. If this CT research yields quicker, more accurate ablations that are more widely available, it will go a long way toward improving the quality of life for these patients.”

Electrical mapping

During electrical or voltage mapping, an electrophysiologist inserts a catheter with an electrode into an artery through the groin and guides it to the beating heart. Fluoroscopic imaging shows the placement of the electrode. The probe detects variations in electrical signals as it is moved a small distance at a time. High voltage indicates normal cardiac tissue. Low or no voltage is associated with dead scar tissue. A computer compiles the data into a map which shows where to apply ablation to eliminate cardiac tissue in and near the scars.

Electrical mapping is laborious and not error-free. Since the probe is moved only small distances, such as five to 15 millimeters at a time for each reading while the heart continues to beat, it may take up to several hours to complete the mapping process and extend the time that the patient is exposed to fluoroscopic X-rays. A scar section that is missed by just a few millimeters during ablation could be the source of additional electrical disturbances. Also, it is possible to get a false electrical reading if the probe does not actually make contact with the heart muscle.

Tian J, Jeudy J, Smith MF, Jimenez A, Yin X, Bruce PA, Lei P, Tergeman A, Abbo A, Shekhar R, Saba M, Shorofsky S, Dickfeld T. “Three dimensional contrast enhanced multi-detector CT for anatomic, dynamic and perfusion characterization of abnormal myocardium to guide VT ablations.” Circulation: Arrhythmia and Electrophysiology. Published online July 24, 2010.

Bill Seiler | EurekAlert!
Further information:

More articles from Medical Engineering:

nachricht Münster researchers make a fly’s heartbeat visible / Software automatically recognizes pulse
12.03.2018 | Westfälische Wilhelms-Universität Münster

nachricht 3-D-written model to provide better understanding of cancer spread
05.03.2018 | Purdue University

All articles from Medical Engineering >>>

The most recent press releases about innovation >>>

Die letzten 5 Focus-News des innovations-reports im Überblick:

Im Focus: Space observation with radar to secure Germany's space infrastructure

Satellites in near-Earth orbit are at risk due to the steady increase in space debris. But their mission in the areas of telecommunications, navigation or weather forecasts is essential for society. Fraunhofer FHR therefore develops radar-based systems which allow the detection, tracking and cataloging of even the smallest particles of debris. Satellite operators who have access to our data are in a better position to plan evasive maneuvers and prevent destructive collisions. From April, 25-29 2018, Fraunhofer FHR and its partners will exhibit the complementary radar systems TIRA and GESTRA as well as the latest radar techniques for space observation across three stands at the ILA Berlin.

The "traffic situation" in space is very tense: the Earth is currently being orbited not only by countless satellites but also by a large volume of space...

Im Focus: Researchers Discover New Anti-Cancer Protein

An international team of researchers has discovered a new anti-cancer protein. The protein, called LHPP, prevents the uncontrolled proliferation of cancer cells in the liver. The researchers led by Prof. Michael N. Hall from the Biozentrum, University of Basel, report in “Nature” that LHPP can also serve as a biomarker for the diagnosis and prognosis of liver cancer.

The incidence of liver cancer, also known as hepatocellular carcinoma, is steadily increasing. In the last twenty years, the number of cases has almost doubled...

Im Focus: Researchers at Fraunhofer monitor re-entry of Chinese space station Tiangong-1

In just a few weeks from now, the Chinese space station Tiangong-1 will re-enter the Earth's atmosphere where it will to a large extent burn up. It is possible that some debris will reach the Earth's surface. Tiangong-1 is orbiting the Earth uncontrolled at a speed of approx. 29,000 km/h.Currently the prognosis relating to the time of impact currently lies within a window of several days. The scientists at Fraunhofer FHR have already been monitoring Tiangong-1 for a number of weeks with their TIRA system, one of the most powerful space observation radars in the world, with a view to supporting the German Space Situational Awareness Center and the ESA with their re-entry forecasts.

Following the loss of radio contact with Tiangong-1 in 2016 and due to the low orbital height, it is now inevitable that the Chinese space station will...

Im Focus: Alliance „OLED Licht Forum“ – Key partner for OLED lighting solutions

Fraunhofer Institute for Organic Electronics, Electron Beam and Plasma Technology FEP, provider of research and development services for OLED lighting solutions, announces the founding of the “OLED Licht Forum” and presents latest OLED design and lighting solutions during light+building, from March 18th – 23rd, 2018 in Frankfurt a.M./Germany, at booth no. F91 in Hall 4.0.

They are united in their passion for OLED (organic light emitting diodes) lighting with all of its unique facets and application possibilities. Thus experts in...

Im Focus: Mars' oceans formed early, possibly aided by massive volcanic eruptions

Oceans formed before Tharsis and evolved together, shaping climate history of Mars

A new scenario seeking to explain how Mars' putative oceans came and went over the last 4 billion years implies that the oceans formed several hundred million...

All Focus news of the innovation-report >>>



Industry & Economy
Event News

New solar solutions for sustainable buildings and cities

23.03.2018 | Event News

Virtual reality conference comes to Reutlingen

19.03.2018 | Event News

Ultrafast Wireless and Chip Design at the DATE Conference in Dresden

16.03.2018 | Event News

Latest News

Don't Give the Slightest Chance to Toxic Elements in Medicinal Products

23.03.2018 | Life Sciences

Sensitive grip

23.03.2018 | Materials Sciences

No compromises: Combining the benefits of 3D printing and casting

23.03.2018 | Process Engineering

Science & Research
Overview of more VideoLinks >>>