New diagnostic method for gout: Dual Energy Computed tomography instead of joint

03.06.2009
The most reliable method of diagnosing gout is to aspirate the joint in order to obtain fluid to verify the presence of monosodiumurate crystals (uric acid). Up to now, computed tomography (CT) has played a limited role in the evaluation of gout, since conventional CT systems cannot reliably verify deposits of uric acid.

However, a current study at the Vancouver General Hospital in Canada gives rise to speculation that dual-energy computed tomography (DECT) could radically change the management of this disease. DECT enables fast, noninvasive examinations and, based on initial evaluations, has the potential to surpass the clinical examination in terms of identifying subclinical disease.

Investigations have confirmed the high sensitivity of the DECT method in detecting uric acid deposits. The Canadian scientists used the SOMATOM Definition computed tomography (CT scanner) from Siemens for their investigation. This systemis the only CT scanner worldwide that features two X-ray tubes capable of simultaneously producing different energies. Gout is the most widespread form of crystal arthopathy and the most common inflammatory joint disease in men. It is caused by the deposition of uric acid crystals in and around joints and predominantly occurs among men. 2.1 million people in the USA and some 1.5 million people in Germany are currently afflicted by this painful, destructive disease.

Furthermore, due to our eating habits, these figures are constantly increasing.

The classical symptoms of gout are painful, visibly swollen joints. Gout is nevertheless difficult to diagnose, since quite a few diseases, for example various forms of arthritis, have similar symptoms. While imaging techniques can help to locate gout lesions, the specificity of X-ray, single-source computed tomography, magnetic resonance imaging and ultrasound is not sufficient to definitively confirm a diagnosis. Certainty can be achieved only by verifying the presence of mono sodium urate crystals, also called uric acid deposits (tophi), in and around the joint. This is done by aspirating the joint with a needle to remove the fluid, which is then microscopically analyzed under polarized light. A joint puncture may be difficult with acutely inflamed joints, since the amount of fluid available may not be sufficient for this purpose. Furthermore, some anatomical regions are difficult to access, for example in the spinal region. A noninvasive diagnostic technique is therefore extremely desirable.

The prospect of a fast, safe and noninvasive diagnosis of gout using dual-energy computed tomography (DECT) has sparked great interest in Canada. In collaboration with Siemens, Dr. Savvas Nicolaou, Director of Emergency Radiology at Vancouver General Hospital and Associate Professor at the University of British Columbia in Vancouver, and both his radiology and rheumatology colleagues developed a dual-energy algorithm for identifying uric acid deposits in gout.

The Canadian scientists used a SOMATOM Definition from Siemens for their trials. This system is the only CT scanner worldwide that features two X-ray tubes capable of simultaneously producing different energies. The team performed scans at different energies to determine the attenuation values of uric acid deposits. Siemens used this data to develop a new dual-energy protocol for gout that now can be used by any physician. The software algorithm used to detect gout via DECT is based on the realization that the CT values of uric acid deposits are lower, for instance, than those of calcium if scans are performed at different energies (80 and 140 kilovolts). Through color coding of the different attenuation values, it then becomes possible to recognize mono sodium urate crystals on the clinical CT image: The uric acid crystals indicating gout are, for example, color coded in red, while other bone formations and calcium are displayed in blue. The commercial version of the Siemens application is called Syngo DE Gout.

In a further study, Dr. Nicolaou and his colleagues investigated whether DECT can be used reliably to confirm the presence of gout tophi, whether DECT is superior to the traditional clinical examination ie detecting subclinical urate deposits, and whether this modality can clarify cases of doubt as a problem solving tool. Ten patients were recruited who already had been diagnosed with gout by means of joint puncture with aspiration of synovial fluid and 10 control patients that did not have gout clinically. The patient records of all patients were analyzed and all patients underwent a complete rheumatological examination and DECT. The evaluation of the DECT images was performed by two radiologists working independently of one another.

This study showed that the DECT images of all patients proven to have gout yielded correspondingly positive findings in the aspirated joints. The DECT images of the control group all showed negative findings. "Our findings indicate that deposits of mono sodium urate crystals can be detected sub clinically more efficiently using DECT than with the traditional clinical examination," says Dr. Nicolaou. The fact is that more areas involved with gout were found overall per DECT than through the other clinical examination ,ie 200 sites with DECT versus 53 sites clinically, ie four times more foci were revealed with DECT(p

Furthermore, it has become evident that DECT can detect the presence of gout in hands, wrists feet, ankles, knees significantly better than the traditional clinical examination. DECT did not achieve significantly better results in the detection of gout in the elbow.

In addition, the study also provided new information on the presence of subclinical tophi and the accumulation of monosodium urate crystal deposits in clinically challenging anatomic regions. "To our surprise, the study showed that uric acid can be initially deposited in tendons and ligaments near and within the knee joint, ankle joint ,wrist , ie in the collateral ligament / cruciate ligament and deep flexor tendons of the wrist", says Dr. Nicolaou. "This is very important to know, since these deposits can increase the susceptibility of tendons and ligaments for tears. If we are able to detect the disease in an early stage, we can initiate a treatment to prevent destruction of the tendons and ligaments and joints where subclinical tophi are present."

"DECT is a promising new technique that can in a reliable, noninvasive fashion confirm the presence of gout tophi subclinically, provide information on the patient's disease burden and enable differentiation from other diseases. This technique may be used for monitoring treatment success and can be used to resolve unclear cases”, says Dr. Nicolaou. However more research is required to more clearly define DECT role in the management of Gout.

The Siemens Healthcare Sector is one of the largest suppliers of healthcare technology worldwide. The company is a medical solution provider with core competencies and innovative strengths in diagnostic and therapeutic technologies as well as knowledge processing, including information technology and system integration. With its acquisitions in laboratory diagnostics, Siemens Healthcare is the first integrated healthcare company that combines imaging and lab diagnostics, therapy solutions and medical information technology and also supplements these with consultation and services.

Siemens Healthcare offers solutions for the entire supply chain under one roof - from prevention and early detection to diagnosis and on to treatment and aftercare. In addition, Siemens Healthcare is the world market leader for innovative hearing instruments. The company employs some 49,000 employees worldwide and is present in more than 130 countries. During fiscal 2008 (ending on September 30), Siemens Healthcare achieved a total sales volume of 11.17 billion euros and incoming orders totaling 11.78 billion euros. The Sector profit from operations amounted to €1.23 billion (preliminary figures).

Marion Bludszuweit | Siemens Healthcare
Further information:
http://www.siemens.com/med-picture/gout
http://www.siemens.com/healthcare

More articles from Medical Engineering:

nachricht First transcatheter implant for diastolic heart failure successful
16.11.2017 | The Ohio State University Wexner Medical Center

nachricht Theranostic nanoparticles for tracking and monitoring disease state
13.11.2017 | SLAS (Society for Laboratory Automation and Screening)

All articles from Medical Engineering >>>

The most recent press releases about innovation >>>

Die letzten 5 Focus-News des innovations-reports im Überblick:

Im Focus: A “cosmic snake” reveals the structure of remote galaxies

The formation of stars in distant galaxies is still largely unexplored. For the first time, astron-omers at the University of Geneva have now been able to closely observe a star system six billion light-years away. In doing so, they are confirming earlier simulations made by the University of Zurich. One special effect is made possible by the multiple reflections of images that run through the cosmos like a snake.

Today, astronomers have a pretty accurate idea of how stars were formed in the recent cosmic past. But do these laws also apply to older galaxies? For around a...

Im Focus: Visual intelligence is not the same as IQ

Just because someone is smart and well-motivated doesn't mean he or she can learn the visual skills needed to excel at tasks like matching fingerprints, interpreting medical X-rays, keeping track of aircraft on radar displays or forensic face matching.

That is the implication of a new study which shows for the first time that there is a broad range of differences in people's visual ability and that these...

Im Focus: Novel Nano-CT device creates high-resolution 3D-X-rays of tiny velvet worm legs

Computer Tomography (CT) is a standard procedure in hospitals, but so far, the technology has not been suitable for imaging extremely small objects. In PNAS, a team from the Technical University of Munich (TUM) describes a Nano-CT device that creates three-dimensional x-ray images at resolutions up to 100 nanometers. The first test application: Together with colleagues from the University of Kassel and Helmholtz-Zentrum Geesthacht the researchers analyzed the locomotory system of a velvet worm.

During a CT analysis, the object under investigation is x-rayed and a detector measures the respective amount of radiation absorbed from various angles....

Im Focus: Researchers Develop Data Bus for Quantum Computer

The quantum world is fragile; error correction codes are needed to protect the information stored in a quantum object from the deteriorating effects of noise. Quantum physicists in Innsbruck have developed a protocol to pass quantum information between differently encoded building blocks of a future quantum computer, such as processors and memories. Scientists may use this protocol in the future to build a data bus for quantum computers. The researchers have published their work in the journal Nature Communications.

Future quantum computers will be able to solve problems where conventional computers fail today. We are still far away from any large-scale implementation,...

Im Focus: Wrinkles give heat a jolt in pillared graphene

Rice University researchers test 3-D carbon nanostructures' thermal transport abilities

Pillared graphene would transfer heat better if the theoretical material had a few asymmetric junctions that caused wrinkles, according to Rice University...

All Focus news of the innovation-report >>>

Anzeige

Anzeige

Event News

Ecology Across Borders: International conference brings together 1,500 ecologists

15.11.2017 | Event News

Road into laboratory: Users discuss biaxial fatigue-testing for car and truck wheel

15.11.2017 | Event News

#Berlin5GWeek: The right network for Industry 4.0

30.10.2017 | Event News

 
Latest News

NASA detects solar flare pulses at Sun and Earth

17.11.2017 | Physics and Astronomy

NIST scientists discover how to switch liver cancer cell growth from 2-D to 3-D structures

17.11.2017 | Health and Medicine

The importance of biodiversity in forests could increase due to climate change

17.11.2017 | Studies and Analyses

VideoLinks
B2B-VideoLinks
More VideoLinks >>>