Forum for Science, Industry and Business

Sponsored by:     3M 
Search our Site:

 

Contrast-enhanced ultrasound monitors aortic aneurysm treatment

15.05.2012
Contrast-enhanced ultrasound is an effective, noninvasive method for monitoring patients who undergo endovascular repair for abdominal aortic aneurysms, according to a new study published in the journal Radiology.

"Our findings support the addition of contrast-enhanced ultrasound as a complementary tool in the follow-up of these patients," said Rosa Gilabert, M.D., Ph.D., from the Hospital Clinic at the University of Barcelona in Spain.

An abdominal aortic aneurysm occurs when the large blood vessel that supplies blood to the abdomen, pelvis and legs becomes abnormally large or balloons outward. Abdominal aortic aneurysms can occur in anyone, but are most commonly found in men over the age of 60 with one or more risk factors, such as smoking, high blood pressure, a positive family history, high cholesterol, peripheral vascular disease or obesity. The aneurysm places stress on the wall of the aorta that can lead to wall rupture. Mortality rates after rupture are high.

Endovascular repair of abdominal aortic aneurysms (EVAR) involves placement of a stent graft called an endograft into the vessel to bypass the area of the aorta weakened by the aneurysm and keep it from rupturing. EVAR has substantially reduced mortality around the time of surgery when compared with open repair. However, EVAR effectiveness can be compromised by a complication, known as an endoleak, which carries the subsequent risk of rupture of the aneurysm sac.

Routine surveillance of endovascular stent placement with computed tomography (CT) angiography enables detection of potential complications in patients with endografts, but it also exposes the patient to ionizing radiation and potential kidney damage from the CT contrast agent.

Dr. Gilabert and colleagues studied ultrasound with a second-generation contrast agent and contrast-specific software as an alternative to CT angiography. The newer contrast agent consists of a suspension of microbubbles similar in size to red blood cells. Because of their small size, the microbubbles do not pass through the cells lining the inner surface of the blood vessel walls and thus provide a pure intravascular contrast agent that allows a real time investigation over several minutes, with the visualization of the dynamic enhancement pattern in real time.

"The main advantage of contrast-enhanced ultrasound is that it offers the possibility of real-time exploration of EVAR-treated patients, without the exposure to ionizing radiation or the risk of damage to the kidneys," she said. 'To avoid the potential risk of kidney toxicity is particularly important, because impaired renal function is not uncommon in these patients."

The researchers evaluated the technique in 35 patients who underwent EVAR. The patients had CT angiography and contrast-enhanced ultrasound studies performed at one- and six-month follow-up and yearly thereafter.

A total of 126 CT angiography and contrast-enhanced ultrasound studies were performed. Contrast-enhanced ultrasound had a sensitivity of 97 percent, a specificity of 100 percent and an accuracy of 99 percent for endoleak detection. The technique enabled correct classification of 26 of 33 endoleaks and did not miss any clinically important endoleak.

"These results support that contrast-enhanced ultrasound can be integrated in the EVAR follow-up," Dr. Gilabert said.

"Evaluation of Abdominal Aortic Aneurysm after Endovascular Repair: Prospective Validation of Contrast-enhanced US with a Second-Generation US Contrast Agent." Collaborating with Dr. Gilabert were Laura Buñesch, M.D., María Isabel Real, M.D., Ph.D., Ángeles García-Criado, M.D., Ph.D., Marta Burrel, M.D., Ph.D., Juan Ramón Ayuso, M.D., Ph.D., Marta Barrufet, M.D., Xavier Montaña, M.D., Ph.D., and Vicenç Riambau, M.D., Ph.D.

Radiology is edited by Herbert Y. Kressel, M.D., Harvard Medical School, Boston, Mass., and owned and published by the Radiological Society of North America, Inc. (http://radiology.rsna.org/)

RSNA is an association of more than 48,000 radiologists, radiation oncologists, medical physicists and related scientists committed to excellence in patient care through education and research. The Society is based in Oak Brook, Ill. (RSNA.org)

For patient-friendly information on ultrasound, visit RadiologyInfo.org.

Linda Brooks | EurekAlert!
Further information:
http://www.rsna.org

More articles from Medical Engineering:

nachricht Rutgers researchers develop automated robotic device for faster blood testing
14.06.2018 | Rutgers University

nachricht Speech comprehension with a cochlear implant
04.06.2018 | Universität zu Lübeck

All articles from Medical Engineering >>>

The most recent press releases about innovation >>>

Die letzten 5 Focus-News des innovations-reports im Überblick:

Im Focus: AchemAsia 2019 will take place in Shanghai

Moving into its fourth decade, AchemAsia is setting out for new horizons: The International Expo and Innovation Forum for Sustainable Chemical Production will take place from 21-23 May 2019 in Shanghai, China. With an updated event profile, the eleventh edition focusses on topics that are especially relevant for the Chinese process industry, putting a strong emphasis on sustainability and innovation.

Founded in 1989 as a spin-off of ACHEMA to cater to the needs of China’s then developing industry, AchemAsia has since grown into a platform where the latest...

Im Focus: First real-time test of Li-Fi utilization for the industrial Internet of Things

The BMBF-funded OWICELLS project was successfully completed with a final presentation at the BMW plant in Munich. The presentation demonstrated a Li-Fi communication with a mobile robot, while the robot carried out usual production processes (welding, moving and testing parts) in a 5x5m² production cell. The robust, optical wireless transmission is based on spatial diversity; in other words, data is sent and received simultaneously by several LEDs and several photodiodes. The system can transmit data at more than 100 Mbit/s and five milliseconds latency.

Modern production technologies in the automobile industry must become more flexible in order to fulfil individual customer requirements.

Im Focus: Sharp images with flexible fibers

An international team of scientists has discovered a new way to transfer image information through multimodal fibers with almost no distortion - even if the fiber is bent. The results of the study, to which scientist from the Leibniz-Institute of Photonic Technology Jena (Leibniz IPHT) contributed, were published on 6thJune in the highly-cited journal Physical Review Letters.

Endoscopes allow doctors to see into a patient’s body like through a keyhole. Typically, the images are transmitted via a bundle of several hundreds of optical...

Im Focus: Photoexcited graphene puzzle solved

A boost for graphene-based light detectors

Light detection and control lies at the heart of many modern device applications, such as smartphone cameras. Using graphene as a light-sensitive material for...

Im Focus: Water is not the same as water

Water molecules exist in two different forms with almost identical physical properties. For the first time, researchers have succeeded in separating the two forms to show that they can exhibit different chemical reactivities. These results were reported by researchers from the University of Basel and their colleagues in Hamburg in the scientific journal Nature Communications.

From a chemical perspective, water is a molecule in which a single oxygen atom is linked to two hydrogen atoms. It is less well known that water exists in two...

All Focus news of the innovation-report >>>

Anzeige

Anzeige

VideoLinks
Industry & Economy
Event News

Munich conference on asteroid detection, tracking and defense

13.06.2018 | Event News

2nd International Baltic Earth Conference in Denmark: “The Baltic Sea region in Transition”

08.06.2018 | Event News

ISEKI_Food 2018: Conference with Holistic View of Food Production

05.06.2018 | Event News

 
Latest News

A sprinkle of platinum nanoparticles onto graphene makes brain probes more sensitive

15.06.2018 | Materials Sciences

100 % Organic Farming in Bhutan – a Realistic Target?

15.06.2018 | Ecology, The Environment and Conservation

Perovskite-silicon solar cell research collaboration hits 25.2% efficiency

15.06.2018 | Power and Electrical Engineering

VideoLinks
Science & Research
Overview of more VideoLinks >>>