Sensor Warns Patients in Advance of Asthma Attack

The sensor measures amounts as small as one ppb (part per billion), making it as sensitive as larger devices that are far more expensive and not portable. One ppb corresponds approximately to the dilution of a cube of sugar in a 50 meter-long swimming pool. The new sensor is contained in a prototype device that will be portable and only a little larger than a cell phone.

In patients suffering from asthma, the latent inflammation of the bronchial tubes generally spreads long before the patients actually feel anything. If the inflammation is intense, the air passages constrict and the patient has an asthma attack. The attacks can be so serious that the patient has to be treated in hospital, which is why many asthma sufferers regularly take anti-inflammatory medication. Previously, the only way to detect impending asthma attacks in advance was to conduct expensive pulmonary examinations to determine if the patient’s breath contained heightened levels of nitrogen monoxide (NO), which signal such an attack. By contrast, the new sensor from Siemens Corporate Technology will enable patients to analyze the NO in their breath themselves. As a result, they will be able to take the minimum amount of preventive medication and increase the dose only if really necessary.

The new sensor can detect increases in NO one day before an acute asthma attack occurs. Over the past few years, medical researchers and health insurance companies have recognized that NO levels are an effective indication of an impending asthma attack. In the analysis of a patient’s breath, the system first converts nitrogen monoxide into nitrogen dioxide, after which the air flows across the actual sensor. Only the particles signaling the attack adhere to the sensor’s surface. This generates a voltage that is measured by a field-effect transistor. The intensity of the voltage is directly dependent on the amount of nitrogen monoxide in the patient’s breath. On the basis of this value, the patient can decide what dose of anti-inflammatory medication he or she should take.

Another type of breath sensor under consideration would allow athletes to check whether they are exercising enough to burn fat. The detection principle is the same, except that the system measures the level of acetone. The latter is generated in the body when fat is burned and is also detectable in a person’s breath.

Media Contact

Dr. Norbert Aschenbrenner Siemens InnovationNews

All latest news from the category: Information Technology

Here you can find a summary of innovations in the fields of information and data processing and up-to-date developments on IT equipment and hardware.

This area covers topics such as IT services, IT architectures, IT management and telecommunications.

Back to home

Comments (0)

Write a comment

Newest articles

High-energy-density aqueous battery based on halogen multi-electron transfer

Traditional non-aqueous lithium-ion batteries have a high energy density, but their safety is compromised due to the flammable organic electrolytes they utilize. Aqueous batteries use water as the solvent for…

First-ever combined heart pump and pig kidney transplant

…gives new hope to patient with terminal illness. Surgeons at NYU Langone Health performed the first-ever combined mechanical heart pump and gene-edited pig kidney transplant surgery in a 54-year-old woman…

Biophysics: Testing how well biomarkers work

LMU researchers have developed a method to determine how reliably target proteins can be labeled using super-resolution fluorescence microscopy. Modern microscopy techniques make it possible to examine the inner workings…

Partners & Sponsors