A new high performance and fault-tolerant datacenter network for modular datacenters was proposed

30.07.2012
A modular datacenter network (MDCN) is the key component in building mega-datacenters.

Huang Feng, Li Dongsheng, and their group from the National Key Laboratory of Parallel and Distributed Processing, School of Computers, National University of Defense Technology present a novel hybrid intra-container network for a modular datacenter (MDC), called SCautz, together with a suite of routing protocols.

SCautz is able to provide high network throughput for various traffic patterns, and achieves graceful performance degradation when failures occur and increase. Their work, entitled "SCautz: a high performance and fault-tolerant datacenter network for modular datacenters", has been published in Science China Information Sciences, 2012, Vol. 55(7).

To construct mega-datacenters, the MDC first packages thousands of servers, which have been set up and wired, into one shipping container, and then connects the containers together by viewing them as large pluggable building blocks. Once connected to power, a cooling infrastructure, and the Internet, the MDC can provide services at any location in the world.

Traditional datacenter networks (DCN) interconnect large numbers of servers directly, making these difficult to realize and maintain. An MDCN consists of intra- and inter-container networks, which largely simplify the design and implementation. Typically, a standard 20 or 40 foot shipping container is equipped with 1200-2500 servers, with the number of servers in a container fixed during its lifetime. A container's moderate scale relaxes the restriction on the scalability of DCNs. So, intra-container networks can adopt more complex topologies.

Although the Kautz graph achieves near-optimal tradeoff between node degree and diameter, and has better bisection width and bottleneck degree, it is considered to be unsuitable for traditional DCNs, due to the difficulty of not violating the original structure in its incremental deployment. For an MDC, on the other hand, the number of servers in a single container is fixed, and the inner network does not change throughout its lifespan. Thus, SCautz was designed by modeling the Kautz graph.

Containerization lowers the total cost of ownership for cloud providers, and allows operators to manage the MDC using a particular "service-free" model. In other words, a container as a whole is never repaired during its deployment lifespan (typically 3-5 years). As long as the performance of the entire container meets an engineered minimum criterion, there is no continuous component repair. However, server failures not only decrease the MDC's computation and storage capacity, but also destroy the MDCN's structure. For instance, BCube is an excellent network architecture for current MDCs. However, due to its incomplete structure, the throughput for one-to-x traffic patterns drops noticeably, while the ABT (aggregate bottleneck throughput) for all-to-all traffic degrades faster than the computation and storage.

Furthermore, switch failures decrease BCube's performance much more significantly, since its ABT deteriorates by more than 50% in the presence of 20% switch failures. The fact that network performance degrades faster than computation or storage capacity is the MDCN's ultimate weakness, since this causes the container's overall performance to decrease below the threshold criterion and end its lifespan prematurely.

Therefore, based on the "scale out" principle, SCautz presents a hybrid structure for dealing with server and switch faults. This comprises a base physical Kautz topology, which is built by interconnecting the servers' NIC ports, and a small number of redundant commercial off-the-shelf (COTS) switches. In SCautz, each switch and a specific number of servers form a "cluster". Since switches are divided into two types according to their identifiers, "clusters" are also divided into two types. If viewed as logical nodes, the two types of "clusters" construct two higher-level logical Kautz structures, respectively, as shown in the figure below. SCautz's hybrid structure has the following advantages.

First, SCautz can run in different modes with switches on or off. Its base topology provides high capacity for processing different types of traffic patterns, and behaves as well as BCube. Moreover SCautz's complete structure is able to improve performance twofold through the use of switches, thereby providing the ability to handle bursts of network flows effectively without lowering the quality of bandwidth-intensive applications.

Second, SCautz improves the fault tolerance of an MDCN by using redundant switches. When a server fails, SCautz finds a peer server in the same cluster to bypass the failed one. Thus, it can maintain the throughput for one-to-x traffic (e.g., one-to-one, one-to-all), and reduce the ABT loss by about a half so that network performance degrades much more slowly than the MDC's computation or storage capacity.

Third, the extra cost of the redundant design is very low. Theoretical analysis shows that a typical SCautz-based container with 1280 servers only needs 160 COTS switches.

The design and implementation of SCautz was a collaborative effort involving many researchers. This research project was partially supported by the National Basic Research Program of China (Grant No. 2011CB302600) and National Natural Science Foundation of China (Grant No. 60903205), amongst others. It is an important breakthrough in modular datacenter network architectures. The researchers suggest that their work needs to be implemented and examined in a larger production datacenter. This work will have significant impact on datacenter construction and cloud computing.

See the article: Huang F, Lu X C, Li D S, et al. SCautz: a high performance and fault-tolerant datacenter network for modular datacenters. Sci China Inf Sci, 2012, 55(7): 1.

HUANG Feng | EurekAlert!
Further information:
http://zh.scichina.com/english/

More articles from Information Technology:

nachricht Researchers illuminate the path to a new era of microelectronics
23.04.2018 | Boston University College of Engineering

nachricht Researchers achieve HD video streaming at 10,000 times lower power
20.04.2018 | University of Washington

All articles from Information Technology >>>

The most recent press releases about innovation >>>

Die letzten 5 Focus-News des innovations-reports im Überblick:

Im Focus: Molecules Brilliantly Illuminated

Physicists at the Laboratory for Attosecond Physics, which is jointly run by Ludwig-Maximilians-Universität and the Max Planck Institute of Quantum Optics, have developed a high-power laser system that generates ultrashort pulses of light covering a large share of the mid-infrared spectrum. The researchers envisage a wide range of applications for the technology – in the early diagnosis of cancer, for instance.

Molecules are the building blocks of life. Like all other organisms, we are made of them. They control our biorhythm, and they can also reflect our state of...

Im Focus: Spider silk key to new bone-fixing composite

University of Connecticut researchers have created a biodegradable composite made of silk fibers that can be used to repair broken load-bearing bones without the complications sometimes presented by other materials.

Repairing major load-bearing bones such as those in the leg can be a long and uncomfortable process.

Im Focus: Writing and deleting magnets with lasers

Study published in the journal ACS Applied Materials & Interfaces is the outcome of an international effort that included teams from Dresden and Berlin in Germany, and the US.

Scientists at the Helmholtz-Zentrum Dresden-Rossendorf (HZDR) together with colleagues from the Helmholtz-Zentrum Berlin (HZB) and the University of Virginia...

Im Focus: Gamma-ray flashes from plasma filaments

Novel highly efficient and brilliant gamma-ray source: Based on model calculations, physicists of the Max PIanck Institute for Nuclear Physics in Heidelberg propose a novel method for an efficient high-brilliance gamma-ray source. A giant collimated gamma-ray pulse is generated from the interaction of a dense ultra-relativistic electron beam with a thin solid conductor. Energetic gamma-rays are copiously produced as the electron beam splits into filaments while propagating across the conductor. The resulting gamma-ray energy and flux enable novel experiments in nuclear and fundamental physics.

The typical wavelength of light interacting with an object of the microcosm scales with the size of this object. For atoms, this ranges from visible light to...

Im Focus: Basel researchers succeed in cultivating cartilage from stem cells

Stable joint cartilage can be produced from adult stem cells originating from bone marrow. This is made possible by inducing specific molecular processes occurring during embryonic cartilage formation, as researchers from the University and University Hospital of Basel report in the scientific journal PNAS.

Certain mesenchymal stem/stromal cells from the bone marrow of adults are considered extremely promising for skeletal tissue regeneration. These adult stem...

All Focus news of the innovation-report >>>

Anzeige

Anzeige

VideoLinks
Industry & Economy
Event News

Invitation to the upcoming "Current Topics in Bioinformatics: Big Data in Genomics and Medicine"

13.04.2018 | Event News

Unique scope of UV LED technologies and applications presented in Berlin: ICULTA-2018

12.04.2018 | Event News

IWOLIA: A conference bringing together German Industrie 4.0 and French Industrie du Futur

09.04.2018 | Event News

 
Latest News

Structured light and nanomaterials open new ways to tailor light at the nanoscale

23.04.2018 | Physics and Astronomy

On the shape of the 'petal' for the dissipation curve

23.04.2018 | Physics and Astronomy

Clean and Efficient – Fraunhofer ISE Presents Hydrogen Technologies at the HANNOVER MESSE 2018

23.04.2018 | Trade Fair News

VideoLinks
Science & Research
Overview of more VideoLinks >>>