Handheld device 'sees' damage in concrete bridges, piers

Engineers at MIT have developed a new technique for detecting damage in concrete bridges and piers that could increase the safety of aging infrastructure by allowing easier, more frequent, onsite inspections that don't interfere with traffic or service.

The technique involves use of a hand-held radar device that can “see”
through the fiberglass-polymer wrapping often used to strengthen aging concrete columns to detect damage behind the wrapping not visible to the naked eye. Such damage can occur on the concrete itself, or to areas where layers of the wrapping have come loose from one another or even debonded from the concrete.

The new noninvasive technique can be used onsite from a distance of more than 10 meters (30 feet) and requires no dismantling or obstruction of the infrastructure. It provides immediate, onsite feedback.

Called FAR-NDT (far-field airborne radar nondestructive testing), the technique could prove especially advantageous for bridges that span rivers or highways, which can prove inaccessible for other inspection techniques. The MIT researchers first reported the technique in the Proceedings of the International Conference on Structural Faults and Repair held in Edinburgh, Scotland, last year.

“The use of radar for detecting hidden defects and deterioration behind covered surfaces offers great potential for wide-range use in assessing the safety of bridges and buildings that have been retrofitted with composite materials,” said Professor Oral Buyukozturk of the Department of Civil and Environmental Engineering (CEE), who developed the technique with CEE graduate student Tzu-Yang Yu and Dennis Blejer of MIT Lincoln Laboratory, where prototype radar measurements were made.

Fiberglass-polymer jacketing–shiny, textured fabric in black or ivory often seen wrapped around concrete columns–is widely used to upgrade existing concrete structures so they can carry a greater load or sustain additional earthquake impact. The wrap is also commonly used to retrofit structures that are damaged or deteriorating from weather or other wear.

Techniques presently available for inspecting these fiberglass-polymer jacketing systems require the inspector to come in direct or close contact with the structure. Some actually require removal of a physical sample, which itself could create a safety issue. The advantage of the new technique is that it allows a rapid inspection from a distance and provides computerized visualization of the internal damages.

“This technique would allow the engineers to perform reliable, in-situ inspection for visualizing and characterizing hidden damages from distances without having to endanger the structure by taking specimens from it, and at the same time, without disturbing the traffic or service,” said Yu, whose Ph.D. thesis will focus on this research. “The project is an excellent example of bridging fundamental science and engineering applications.”

The researchers have demonstrated the validity and potential of the new technique through experiments and computer simulations by sending and receiving radar signals using a “horn” antenna to inspect bridge piers from distances of more than 10 meters. In their experiments, a horn antenna transmits a radar signal to a fiber-wrapped concrete specimen, which reflects the signal back to the antenna. The collected data are then converted by an imaging algorithm into a visualization of the interior of the specimen, including any damage.

The researchers say that the concept has been validated by their initial experimental results using an existing prototype radar system and by computer simulations. Future development of appropriate portable radar equipment for onsite use is necessary before the system can be placed in widespread use by industry.

The work is funded by the National Science Foundation.

Written by Denise Brehm, Civil and Environmental Engineering

Media Contact

Elizabeth A. Thomson MIT News Office

More Information:

http://www.mit.edu

All latest news from the category: Architecture and Construction

Back to home

Comments (0)

Write a comment

Newest articles

High-energy-density aqueous battery based on halogen multi-electron transfer

Traditional non-aqueous lithium-ion batteries have a high energy density, but their safety is compromised due to the flammable organic electrolytes they utilize. Aqueous batteries use water as the solvent for…

First-ever combined heart pump and pig kidney transplant

…gives new hope to patient with terminal illness. Surgeons at NYU Langone Health performed the first-ever combined mechanical heart pump and gene-edited pig kidney transplant surgery in a 54-year-old woman…

Biophysics: Testing how well biomarkers work

LMU researchers have developed a method to determine how reliably target proteins can be labeled using super-resolution fluorescence microscopy. Modern microscopy techniques make it possible to examine the inner workings…

Partners & Sponsors