MRI techniques improve pulmonary embolism detection

Pulmonary embolism occurs when a blood clot—usually from the leg—travels to the lung and blocks the pulmonary artery or one of its main branches. CT angiography is the gold standard for diagnosis, but it exposes patients to ionizing radiation and iodinated contrast agent, which carries a risk of allergic reactions and kidney damage in some patients.

“MRI is developing much faster than CT,” said Diego R. Martin, M.D., Ph.D., head of the Department of Radiology at the University of Arizona College of Medicine in Tucson. “The images we're getting are already significantly better than they were a year ago. There is no doubt that in the future we will be able to offer a non-radiation-based alternative to CT for the diagnosis of pulmonary embolism.”

MRI has been used for pulmonary embolism detection in pregnant women and patients whose kidneys may be harmed by CT angiography contrast agents. However, the Prospective Investigation of Pulmonary Embolism Diagnosis III (PIOPED III) study, a major multicenter trial, found that centers had difficulty obtaining adequate quality MR pulmonary angiography (MRPA) for suspected pulmonary embolism. The PIOPED researchers determined that MRPA should be considered only at centers that routinely perform it and perform it well, and for patients who have contraindications to standard tests.

In the new study, the research team assessed the impact of two additional MRI sequences on MRPA's accuracy. The two techniques—contrast-enhanced volumetric interpolated breath-hold examination (VIBE) and non-contrast true fast imaging with steady-state precession (true FISP)—complement MRPA, according to Dr. Martin.

The addition of VIBE provides a gray scale that enables readers to distinguish between the clot, or thrombus, and the lung, which both appear dark on MRPA.

“Also, VIBE is not time sensitive,” Dr. Martin said. “If the patient coughs, you can do it again. You don't have that option with MRPA.”

The true FISP test does not require contrast agent or a breath hold, an important consideration for embolism patients who often cannot hold their breath long enough for image acquisition on MRPA.

When Dr. Martin and colleagues studied the three techniques on 22 patients with CTA diagnosis of pulmonary embolism, they found a sensitivity of 55 percent, 67 percent and 73 percent for MRPA, true FISP and VIBE, respectively. Combining all three MRI sequences improved the overall detection rate to 84 percent. Specificity was 100 percent for all detection methods except for MRPA, which demonstrated one false positive.

Dr. Martin hopes his findings stimulate discussion of a new, redesigned PIOPED study.

“PIOPED III did not answer the question of whether or not MRI is a useful alternative to CT, because it didn't use all the tools available,” he said.

The MRI sequences used in the study are offered on all the major vendor systems, according to Dr. Martin, with the entire three-sequence protocol taking only 15 minutes to set up and perform.

“MR Imaging of Pulmonary Embolism: Diagnostic Accuracy of Contrast-enhanced 3D MR PulmonaryAngiography, Contrast-enhanced Low–Flip Angle 3D GRE, and Nonenhanced Free-induction FISP Sequences.” Collaborating with Dr. Martin were Bobby Kalb, M.D., Puneet Sharma, Ph.D., Stefan Tigges, M.D., M.S.C.R., Gaye L. Ray, N.P., Hiroumi D. Kitajima, Ph.D., James R. Costello, M.D., Ph.D., and Zhengjia Chen, Ph.D.

Radiology is edited by Herbert Y. Kressel, M.D., Harvard Medical School, Boston, Mass., and owned and published by the Radiological Society of North America, Inc. (http://radiology.rsna.org/)

RSNA is an association of more than 48,000 radiologists, radiation oncologists, medical physicists and related scientists committed to excellence in patient care through education and research. The Society is based in Oak Brook, Ill. (RSNA.org)

For patient-friendly information on MR angiography, visit RadiologyInfo.org.

Media Contact

Linda Brooks EurekAlert!

More Information:

http://www.rsna.org

All latest news from the category: Medical Engineering

The development of medical equipment, products and technical procedures is characterized by high research and development costs in a variety of fields related to the study of human medicine.

innovations-report provides informative and stimulating reports and articles on topics ranging from imaging processes, cell and tissue techniques, optical techniques, implants, orthopedic aids, clinical and medical office equipment, dialysis systems and x-ray/radiation monitoring devices to endoscopy, ultrasound, surgical techniques, and dental materials.

Back to home

Comments (0)

Write a comment

Newest articles

Lighting up the future

New multidisciplinary research from the University of St Andrews could lead to more efficient televisions, computer screens and lighting. Researchers at the Organic Semiconductor Centre in the School of Physics and…

Researchers crack sugarcane’s complex genetic code

Sweet success: Scientists created a highly accurate reference genome for one of the most important modern crops and found a rare example of how genes confer disease resistance in plants….

Evolution of the most powerful ocean current on Earth

The Antarctic Circumpolar Current plays an important part in global overturning circulation, the exchange of heat and CO2 between the ocean and atmosphere, and the stability of Antarctica’s ice sheets….

Partners & Sponsors