Water method for unsedated colonoscopy; interval between prep and colonoscopy predicts prep quality

03.03.2009
GIE: Gastrointestinal Endoscopy special issue: Colonoscopy for colorectal neoplasia

In recognition of National Colorectal Cancer Awareness Month during March, GIE: Gastrointestinal Endoscopy has put out a special issue on colonoscopy for colorectal neoplasia. Studies of note regarding colonoscopy appear in both the monthly March issue and the special issue.

A study appearing in the March issue from researchers in California focuses on the impact of a novel water method on scheduled unsedated colonoscopy in U.S. veterans. Researchers in Texas looked at how the time interval between the completion of the last dose of bowel preparation and the start of colonoscopy predicts the quality of the bowel preparation in a study appearing in the special issue. GIE: Gastrointestinal Endoscopy is the monthly peer-reviewed scientific journal of the American Society for Gastrointestinal Endoscopy (ASGE).

Endoscopy is a procedure that uses an endoscope -- a thin, flexible tube with a light and a lens on the end to look into the esophagus, stomach, duodenum, small intestine, colon, or rectum, in order to diagnose or treat a condition. There are many types of endoscopy, including colonoscopy, sigmoidoscopy, gastroscopy, enteroscopy, and esophogogastroduodenoscopy (EGD). Colonoscopy is frequently used to screen for colorectal cancer, which most typically develops from polyps (growths in the colon).

March Issue: "Impact of a novel water method on scheduled unsedated colonoscopy in U.S. veterans"

During a colonoscopy, the colon must be distended (expanded) in order to pass the colonoscope through the full length of the colon to the cecum (the cul-de-sac lying below the terminal ileum forming the first part of the large intestine or colon ). The advancement of the scope into the cecum is termed cecal intubation and is mandatory for colonoscopy to be effective. Air is the usual medium to distend the bowel. However, air insertion can lengthen the colon (much like an accordion) and result in discomfort that may prevent cecal intubation, particularly in the unsedated patient.

The authors of this study used warm water, rather than air, to distend the colon based on their prior experience with this technique. They previously found that when water was infused into the colon instead of air during colonoscope insertion, approximately 50 percent of the colon exams could be completed without sedation. Based on this background information, researchers in California hypothesized that the novel water method would enhance cecal intubation and increase the proportion of patients willing to have another colonoscopy with no sedation.

An unsedated colonoscopy program was instituted in 2002 at the Veterans Affairs Sepulveda Ambulatory Care Center in California. From June 2005 to May 2006, the air method was used for colonoscopy. From June 2006 to October 2007 the water method was used. With the latter method, the air pump was disabled and "warm to touch" tap water in lieu of air was used. Sixty-two veterans were examined using the air method and 63 veterans were examined using the water method. The cecal intubation rate with the air method was 76 percent, while the water method was 97 percent. The proportion of patients who reported a willingness to repeat an unsedated colonoscopy was significantly higher with the water method at 90 percent compared with 69 percent for the air method.

This was a single center, observational, nonrandomized study in a small elderly male population. Despite these limitations, researchers note that the positive findings of enhanced cecal intubation rates, increased patient reported willingness to have another colonoscopy and improved cleanliness of the colon are sufficiently provocative to warrant calling for their confirmation by a randomized controlled trial with patients in the U.S. for unsedated colonoscopy.

Special Issue: "Duration of the interval between the completion of bowel preparation and the start of colonoscopy predicts bowel-preparation quality"

Recent studies suggest that colonoscopies done in the morning have better quality bowel preparations than those done in the afternoon; furthermore, preparations taken partially on the day of the exam are more effective than those taken entirely the day prior to the test. The right colon is particularly susceptible to inadequate cleansing. Effective bowel preparation is important for doctors to be able to clearly see the colon to look for abnormalities. Inadequate bowel preparation results in decreased rates of cecal intubation, increased rates of missing important lesions, increased patient discomfort and may result in cancellation or repetition of the colonoscopy.

Researchers at the Dallas Veteran's Affairs Medical Center noted an unacceptably high rate of inadequate bowel preparations and initiated a study to explore how to improve that rate. The primary aim of the study was to determine how the duration of the interval between the end of the preparation and the start of the colonoscopy affects preparation quality.

Between July and October 2007, 378 outpatients between the ages of 18 and 85 (96 percent men, mean age 62.2 years) were scheduled for elective colonoscopy. All patients were instructed to avoid iron supplements starting seven days before the colonoscopy. Two days before the procedure, patients were told to start a low-fiber diet. On the day before the procedure, patients were advised to drink only clear liquids and to avoid all solid foods. Study patients received one of three bowel preparations based on their ability to tolerate previous bowel preparations and on the presence of renal insufficiency and other comorbidities. The preparations used were polyethelene glycol electrolyte-based (PEG) and sodium phosphate (SP) solution (71 percent), oral PEG and magnesium citrate (23 percent), or SP alone (6 percent). The time of the final bowel preparation dose and the start time of the colonoscopy were recorded.

The physicians graded the overall quality of the preparation according to a scale developed by 10 experienced endoscopists at their center. The bowel preparation quality scale permitted a score of 4-unsatisfactory, 3-poor, 2-fair, 1-good, and 0-excellent. In the group as a whole, 52 percent had an excellent or good bowel preparation, 34 percent had a fair preparation, and 14 percent had a preparation rated poor or unsatisfactory. There was no difference between the three preparation varieties.

Patients with excellent or good bowel preparations (score 0-1) had a significantly shorter interval between the last preparation dose and the start of the colonoscopy (13.6 hours) when compared to patients with unsatisfactory to fair bowel preparations (14.35 hours). The researchers estimated that for every additional hour that the patient waits between the last preparation and the colonoscopy, the chance of having a good or excellent rating decreases by almost 10 percent.

In conclusion, researchers found that it is the duration of the interval between the completion of bowel preparation and the start of colonoscopy that is a major determinant of bowel preparation quality and a better determinant than the time of day when the colonoscopy is performed. Colonoscopy should begin a minimum of 14 hours following the last dose of bowel preparation to minimize the risk of an unsatisfactory preparation. In light of the findings, they adopted a split-dose bowel preparation regimen in their unit. In a split-dose regimen, the patient takes a portion of the bowel preparation solution the evening prior to the procedure with the second dose taken the day of the colonoscopy. The second dose minimizes the interval between preparation and colonoscopy, and this technique has been shown to result in superior bowel preparation by other investigators.

Anne Brownsey | EurekAlert!
Further information:
http://www.asge.org

More articles from Studies and Analyses:

nachricht First form of therapy for childhood dementia CLN2 developed
25.04.2018 | Universitätsklinikum Hamburg-Eppendorf

nachricht Do microplastics harbour additional risks by colonization with harmful bacteria?
05.04.2018 | Leibniz-Institut für Ostseeforschung Warnemünde

All articles from Studies and Analyses >>>

The most recent press releases about innovation >>>

Die letzten 5 Focus-News des innovations-reports im Überblick:

Im Focus: BAM@Hannover Messe: innovative 3D printing method for space flight

At the Hannover Messe 2018, the Bundesanstalt für Materialforschung und-prüfung (BAM) will show how, in the future, astronauts could produce their own tools or spare parts in zero gravity using 3D printing. This will reduce, weight and transport costs for space missions. Visitors can experience the innovative additive manufacturing process live at the fair.

Powder-based additive manufacturing in zero gravity is the name of the project in which a component is produced by applying metallic powder layers and then...

Im Focus: Molecules Brilliantly Illuminated

Physicists at the Laboratory for Attosecond Physics, which is jointly run by Ludwig-Maximilians-Universität and the Max Planck Institute of Quantum Optics, have developed a high-power laser system that generates ultrashort pulses of light covering a large share of the mid-infrared spectrum. The researchers envisage a wide range of applications for the technology – in the early diagnosis of cancer, for instance.

Molecules are the building blocks of life. Like all other organisms, we are made of them. They control our biorhythm, and they can also reflect our state of...

Im Focus: Spider silk key to new bone-fixing composite

University of Connecticut researchers have created a biodegradable composite made of silk fibers that can be used to repair broken load-bearing bones without the complications sometimes presented by other materials.

Repairing major load-bearing bones such as those in the leg can be a long and uncomfortable process.

Im Focus: Writing and deleting magnets with lasers

Study published in the journal ACS Applied Materials & Interfaces is the outcome of an international effort that included teams from Dresden and Berlin in Germany, and the US.

Scientists at the Helmholtz-Zentrum Dresden-Rossendorf (HZDR) together with colleagues from the Helmholtz-Zentrum Berlin (HZB) and the University of Virginia...

Im Focus: Gamma-ray flashes from plasma filaments

Novel highly efficient and brilliant gamma-ray source: Based on model calculations, physicists of the Max PIanck Institute for Nuclear Physics in Heidelberg propose a novel method for an efficient high-brilliance gamma-ray source. A giant collimated gamma-ray pulse is generated from the interaction of a dense ultra-relativistic electron beam with a thin solid conductor. Energetic gamma-rays are copiously produced as the electron beam splits into filaments while propagating across the conductor. The resulting gamma-ray energy and flux enable novel experiments in nuclear and fundamental physics.

The typical wavelength of light interacting with an object of the microcosm scales with the size of this object. For atoms, this ranges from visible light to...

All Focus news of the innovation-report >>>

Anzeige

Anzeige

VideoLinks
Industry & Economy
Event News

Invitation to the upcoming "Current Topics in Bioinformatics: Big Data in Genomics and Medicine"

13.04.2018 | Event News

Unique scope of UV LED technologies and applications presented in Berlin: ICULTA-2018

12.04.2018 | Event News

IWOLIA: A conference bringing together German Industrie 4.0 and French Industrie du Futur

09.04.2018 | Event News

 
Latest News

Getting electrons to move in a semiconductor

25.04.2018 | Physics and Astronomy

Reconstructing what makes us tick

25.04.2018 | Physics and Astronomy

Cheap 3-D printer can produce self-folding materials

25.04.2018 | Information Technology

VideoLinks
Science & Research
Overview of more VideoLinks >>>