Lead levels in drinking water spike when copper and lead pipes joined

19.12.2011
Levels linked to galvanic corrosion, disinfectants, pH

Lead pipes once used routinely in municipal water distribution systems are a well-recognized source of dangerous lead contamination, but new research from Washington University in St. Louis suggests that the partial replacement of these pipes can make the problem worse.

The research shows that joining old lead pipes with new copper lines using brass fittings spurs galvanic corrosion that can dramatically increase the amount of lead released into drinking water supplies.

“Work done in our laboratory shows galvanic corrosion in joined service lines is significant and lasts for a long time,” says Dan Giammar, PhD, the Harold D. Jolley Career Development Associate Professor in the Department of Energy, Environmental & Chemical Engineering at Washington University in St. Louis.

His study, published in the Proceedings of the 2011 Water Quality Technology Conference, suggests that safety-minded, lead-pipe-removal programs at water utilities across the country actually may be increasing the risk of lead exposure for water customers.

An experiment running in his aquatic chemistry lab shows why. It features 80- to 100-year-old lead water pipes that were dug out of the ground in Washington, D.C., and shipped to his St. Louis laboratory. Some of the lead pipes have been cut and then joined with brass couplings to brand new copper pipe.

This setup mimics what happens if a utility company is replacing lead service lines and homeowners decline to have their sections of the lines replaced.

A service line runs from the main to the home. The utility owns the part from the main to the homeowner's property line and the homeowner owns the part from the property line to the house. The utility cannot replace the homeowner’s half of the line unless the homeowner gives permission and pays for replacement. In the U.S. only 10 percent of homeowners agree to the charge.

“Since you started with a whole lead pipe and you now have half a lead pipe, you might think your problem would be half of what it was or — maybe — completely unchanged,” Giammar says.

His experiment reveals that instead, it could be far worse. The joined lead-copper pipe in his lab releases five times more lead than did the original lead pipe.

The lead is released by galvanic corrosion, a process set up whenever two dissimilar metals are immersed in a conducting liquid.

The same thing happens if lasagna or another acidic dish is made in a stainless steel pan, covered with aluminum foil, and placed in a refrigerator. The two metals and the lasagna act as a galvanic cell, and some of the aluminum may migrate out of the foil and plate out on the surface of the lasagna.

The Lead and Copper Rule
The project to measure galvanic corrosion of lead pipes was the third Giammar has done for the Water Research Foundation, an organization of water utilities that allows them to pool their money to support research on problems of common interest.

Giammar, who calls himself a heavy metals guy, did his doctoral work on uranium contamination of soil and groundwater, work relevant to the far-flung branches of the Manhattan Project that purified uranium for the atomic bomb during World War II.

He still works on uranium remediation, but when he moved to St. Louis in 2002, he thought that he really ought to work on lead as well, because Missouri has historically been one of the two largest lead-producing states in the country. The other is Alaska.

Giammar began with experiments directed at understanding exactly what happens when phosphates are worked into lead contaminated soil. Under the right conditions, the phosphate will bind to the lead and immobilize it.

Phosphate remediation of lead contaminated soils had been successful in Joplin, Mo., a town located in the Tri-State district, an historic lead-zinc mining district that takes in parts of Missouri, Kansas and Oklahoma.

While Giammar was working with phosphates and soils, the media began reporting that lead levels in the tap water in Washington, D.C., were higher than before and indeed were higher than national drinking water standards allowed.

Lead, as Giammar says, is a “xenobiotic” element (literally foreign to living systems). Unlike some metals, it serves no biological purpose and only does harm. But lead pipes weren’t outlawed in new construction until 1978.

That the district knew it had a problem was remarkable in itself. The levels of lead in drinking water weren’t regulated until 1991, when the Lead and Copper Rule was passed.

The lead levels in Washington, D.C., drinking water began to rise in 2001.

The case of Washington, D.C., water

The lead levels rose for an interesting reason, says Giammar. The district water utility was trying to improve water quality.

In the U.S., he explains, water is delivered with a disinfectant still in it. There are two ways of chlorinating water to disinfect it. Utilities either use free chlorine, which is essentially bleach, or they use chloramines, which are essentially bleach combined with ammonia.

Free chlorine is a better disinfectant but it also forms higher concentrations of chlorinated disinfection byproducts — things like chloroform — that we don’t want in our drinking water, Giammar says.

In an effort to decrease the concentrations of disinfection byproducts, the district switched from chlorine to chloramine.

This is where the water chemistry comes in. “The lead pipe, in itself, is not much of a concern,” Giammar says. Pure lead, lead 0 as it’s called, is not particularly reactive or soluble, which is one of the reasons people made plumbing out of it. Lead pipes last much longer than iron pipes.

But lead can oxidize — essentially corrode. The lead species that then form determine how much lead ends up in the water. The various forms of lead in the +2 oxidation state are all more soluble than lead 0, but lead sulfate is more soluble than lead carbonate, which is in turn more soluble than lead phosphate. (The oxidation state of an element is a rough measure of how many electrons it has "lost to other, nearby elements that are attracting the electrons more strongly.)

When it comes to lead in the +4 oxidation state there’s a twist.

“If you have a strong oxidant, you can form species with lead in the +4 oxidation state,” Giammar says. “These have very low solubility but they’re only stable in the presence of a strong oxidant. As soon as the strong oxidant goes away, the lead +4 is no longer stable. It starts to come back to lead +2, and it can release the lead quite quickly.”

The free chlorine the district had been using is a very strong oxidant. The chloramines they switched to are less strong.

“So when they switched to chloramines, the pipe scale that had formed over years of chlorine treatment began to release lead into the water,” Giammar says. It was a classic example of an unintended consequence.

What the district case demonstrates, Giammar says, is that tap water is a manufactured product, not a natural resource. The water leaving the treatment plant can have essentially no lead in it, but by the time it reaches the faucet that could have changed.

The lead comes from the piping, but whether it is released depends on the chemistry of the water running through the distribution system.

Looking at water chemistry
When he read about the district problem, Giammar wrote a proposal to the Water Research Board offering to study the chemistry of the insides of pipes, particularly the dissolution rates of lead phosphates, lead carbonates and the lead +4 oxides, as a function of pH, added phosphate and disinfectants.

“That was our first entry into the field of lead and drinking water,” he says.

“We knew pH would be an important variable,” he says. “You don’t want your pH to fall too low, especially for the lead carbonates, which dissolve at lower pH.”

“But we didn’t realize how important pH was. We studied water samples with a pH of 10, 8.5 and 7.5. You wouldn’t think there would be a much of a difference between a pH of 8.5 and 7.5, but there was.

“In some cases, the pH made the difference between a lead concentration that met the drinking water standard and one that didn’t.”

Phosphate also turned out to be important. “It had a huge impact on the dissolution rates of all the lead corrosion products we studied,” says Giammar.

So one way to bring down lead levels is to add phosphate. But phosphate costs money, so the utilities want to add as little of it as they can to produce a good-quality water.

“It’s never going to be a one-size-fits all solution because the source-water compositions are different,” says Giammar, “but we came up with some pretty strong recommendations.”

The final report on the project, “Influence of Water Chemistry on the Dissolution and Transformation Rates of Lead Corrosion Products,” was published last year.

Should you let the tap run?
“Another thing we studied in that first project,” Giammar says, “was whether we should be more worried about reaction rates or about the equilibrium state of the reactions.

“To put it another way, if you let the water sit in the pipes for six hours, will it be different from water that sat in the pipes for only an hour?”

It turned out that most lead species dissolve relatively quickly, so reaction rates are not particularly important. The water is the same no matter how long the water has been sitting in the pipes.

But this isn’t true of the lead +4 oxides, the material that formed the scale inside the Washington, D.C., pipes. “They are never at equilibrium with the water flowing over them,” Giammar says. “Instead everything depends on the rate at which those oxides form or the rate at which they dissolve.”

So Giammar proposed a second project for the Water Research Foundation just to study the lead +4 oxides. “They’re fascinating solids,” he says.

Then Giammar’s lab picked up a third project. “A little over a year ago, I got a call from an environmental engineer in Washington, D.C., who was looking at something called galvanic corrosion and its potential to release lead into drinking water,“ he says.

This is the project that led to the centenarian lead pipe experiment now taking up much of the bench space in his lab.

Unlike some of the other water problems he has studied, galvanic corrosion is national in scope. The Environmental Protection Agency is concerned enough that it has appointed a science advisory board to make recommendations on how best to deal with it, Giammar says.

How low can we go?
It’s difficult to talk about lead in a sensible way. The current threshold for drinking water is 15 micrograms per liter, Giammar says. And while there’s talk in the community about lowering the allowable levels of some water contaminants, lead is not among them.

Environmental lead is ubiquitous and everyone has measurable levels of lead in their blood. We are exposed to it through dust and air as well as through water, thanks in part to the tetraethyl lead added to gasoline as an antiknock compound for 80 years.

“If your dominant exposure is through dust, there’s little benefit to ratcheting down your exposure to water even further,” Giammar says.

But, he says, because of the Lead and Copper Rule, water utilities now monitor lead levels. And he learned at a recent conference that during the most recent monitoring period, only 30 utilities had lead levels above the drinking water standard.

That may seem like a lot, he said, but there are roughly 54,000 water utilities in the U.S.

Diana Lutz | EurekAlert!
Further information:
http://www.wustl.edu

More articles from Studies and Analyses:

nachricht Real-time feedback helps save energy and water
08.02.2017 | Otto-Friedrich-Universität Bamberg

nachricht The Great Unknown: Risk-Taking Behavior in Adolescents
19.01.2017 | Max-Planck-Institut für Bildungsforschung

All articles from Studies and Analyses >>>

The most recent press releases about innovation >>>

Die letzten 5 Focus-News des innovations-reports im Überblick:

Im Focus: Breakthrough with a chain of gold atoms

In the field of nanoscience, an international team of physicists with participants from Konstanz has achieved a breakthrough in understanding heat transport

In the field of nanoscience, an international team of physicists with participants from Konstanz has achieved a breakthrough in understanding heat transport

Im Focus: DNA repair: a new letter in the cell alphabet

Results reveal how discoveries may be hidden in scientific “blind spots”

Cells need to repair damaged DNA in our genes to prevent the development of cancer and other diseases. Our cells therefore activate and send “repair-proteins”...

Im Focus: Dresdner scientists print tomorrow’s world

The Fraunhofer IWS Dresden and Technische Universität Dresden inaugurated their jointly operated Center for Additive Manufacturing Dresden (AMCD) with a festive ceremony on February 7, 2017. Scientists from various disciplines perform research on materials, additive manufacturing processes and innovative technologies, which build up components in a layer by layer process. This technology opens up new horizons for component design and combinations of functions. For example during fabrication, electrical conductors and sensors are already able to be additively manufactured into components. They provide information about stress conditions of a product during operation.

The 3D-printing technology, or additive manufacturing as it is often called, has long made the step out of scientific research laboratories into industrial...

Im Focus: Mimicking nature's cellular architectures via 3-D printing

Research offers new level of control over the structure of 3-D printed materials

Nature does amazing things with limited design materials. Grass, for example, can support its own weight, resist strong wind loads, and recover after being...

Im Focus: Three Magnetic States for Each Hole

Nanometer-scale magnetic perforated grids could create new possibilities for computing. Together with international colleagues, scientists from the Helmholtz Zentrum Dresden-Rossendorf (HZDR) have shown how a cobalt grid can be reliably programmed at room temperature. In addition they discovered that for every hole ("antidot") three magnetic states can be configured. The results have been published in the journal "Scientific Reports".

Physicist Dr. Rantej Bali from the HZDR, together with scientists from Singapore and Australia, designed a special grid structure in a thin layer of cobalt in...

All Focus news of the innovation-report >>>

Anzeige

Anzeige

Event News

Booth and panel discussion – The Lindau Nobel Laureate Meetings at the AAAS 2017 Annual Meeting

13.02.2017 | Event News

Complex Loading versus Hidden Reserves

10.02.2017 | Event News

International Conference on Crystal Growth in Freiburg

09.02.2017 | Event News

 
Latest News

Stingless bees have their nests protected by soldiers

24.02.2017 | Life Sciences

New risk factors for anxiety disorders

24.02.2017 | Life Sciences

MWC 2017: 5G Capital Berlin

24.02.2017 | Trade Fair News

VideoLinks
B2B-VideoLinks
More VideoLinks >>>